Baxter AS50 Infusion Pump

Baxter AS50 Infusion Pump

Baxter | SKU : BX-AS50
Call For Pricing : 1-800-507-8244
 
(0 reviews)  

Developed to meet the infusion needs in NICU, Anesthesia and Critical Care, the Baxter Auto Syringe AS50 Infusion Pumpdelivers precise, controlled infusions.

Download Document of Baxter AS50 Infusion Pump.
Discount Cardiology ships via the Federal Express Service, which delivers shipments anywhere in the United States -- usually within 2-5 business days -- at low rates. Unless specified, shipping charges are added to each order based on the specific order.
Quick Review

Developed to meet the infusion needs in NICU, Anesthesia and Critical Care, the Baxter Auto Syringe AS50 Infusion Pumpdelivers precise, controlled infusions.

Shipping
Discount Cardiology ships via the Federal Express Service, which delivers shipments anywhere in the United States -- usually within 2-5 business days -- at low rates. Unless specified, shipping charges are added to each order based on the specific order.

Baxter AS50 Infusion/Syringe Pump

Dimensions:

  • Approx. 3.4"W x 2.6"D x 10"H

Weight:

  • Approx. 3.2 lbs.

Flow Rate Accuracy:

  • ± 3% of full scale plunger travel (not including syringe tolerance)

Volume Accuracy:

  • ± 3%, or 0.007" of travel, whichever is greater (not including syringe tolerance)

Syringes:

  • B-D: 1, 3, 5, 10, 20, 30, 60 mL plastic
  • Monoject: 1, 3, 6, 12, 20, 35, 60 mL
  • Terumo: 1, 3, 5, 10, 20, 30, 60 mL

Flow Rate Range:

  • 0.01 mL/hr to 438 mL/hr, depending on the syringe

Delivery Volume:

  • Full syringe volume for 1-60 mL syringes

Data Display:

  • Self-prompting, multi-field LCD (Liquid Crystal Display)

Status Display:

  • Nine-LED (Light Emitting Diode) array

Power Requirements:

  • AC: 105-125V 60 Hz (battery charger)
  • DC: internal rechargeable battery pack

Battery Operating Time:

  • 5 hours of operation at 100 mL/hr, or 12 hours of operation at 2 mL/hr using a 60 mL syringe, following a charge of not less than 16 hours.

Temperature Range:

  • 50º F to 104º F (10º C to 40º C) Delivery of high viscosity fluids at low temperatures is not recommended

Keypad:

  • Elastomeric type, with tactile feedback

Construction:

  • Water-resistant, high-impact plastic case with removable protective bumpers

Fully Refurbished with a 1 yr warranty!

There have been no reviews


: *
: *
: *
 
Description

Baxter AS50 Infusion/Syringe Pump

Dimensions:

  • Approx. 3.4"W x 2.6"D x 10"H

Weight:

  • Approx. 3.2 lbs.

Flow Rate Accuracy:

  • ± 3% of full scale plunger travel (not including syringe tolerance)

Volume Accuracy:

  • ± 3%, or 0.007" of travel, whichever is greater (not including syringe tolerance)

Syringes:

  • B-D: 1, 3, 5, 10, 20, 30, 60 mL plastic
  • Monoject: 1, 3, 6, 12, 20, 35, 60 mL
  • Terumo: 1, 3, 5, 10, 20, 30, 60 mL

Flow Rate Range:

  • 0.01 mL/hr to 438 mL/hr, depending on the syringe

Delivery Volume:

  • Full syringe volume for 1-60 mL syringes

Data Display:

  • Self-prompting, multi-field LCD (Liquid Crystal Display)

Status Display:

  • Nine-LED (Light Emitting Diode) array

Power Requirements:

  • AC: 105-125V 60 Hz (battery charger)
  • DC: internal rechargeable battery pack

Battery Operating Time:

  • 5 hours of operation at 100 mL/hr, or 12 hours of operation at 2 mL/hr using a 60 mL syringe, following a charge of not less than 16 hours.

Temperature Range:

  • 50º F to 104º F (10º C to 40º C) Delivery of high viscosity fluids at low temperatures is not recommended

Keypad:

  • Elastomeric type, with tactile feedback

Construction:

  • Water-resistant, high-impact plastic case with removable protective bumpers

Fully Refurbished with a 1 yr warranty!

Customer feedback
There have been no reviews


Send to friend
: *
: *
: *