Technical Parameters

  • Display Format: LCD
  • Back light: LED
  • SPO2:35-99%
  • Pulse Ratio:30-250 BPM
  • Pulse Wave: LCD Graphic Display
  • Battery Voltage Low Indication: LCD signals.
  • Power Requirements: Two AA size 1.5V Alkali Battery;
  • Power Consumption: less than 20 mA.
  • Resolution: ±1% for SPO2 and ±1 BPM for Pulse Ratio.
  • Measurement Accuracy: ±2% in stage of 70% % SPO2 and meaningless when stage being smaller than 70%. ±2BPM for Pulse Ratio.
  • Measurement Performance in Weak Filling Condition : Oxyhemoglobin and pulse & value can be shown correctly when pulse-filling ratio is 0.4%.
  • Interference Resistance Capacity against Ambient Light : Deviation is smaller than ±1% between & value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room.
  • It is equipped with a function switch, through which the Oximeter can be automatically powered off when no finger is in the Oximeter more than 8 seconds.
There have been no reviews


: *
: *
: *
 
Description

Product Description

Technical Parameters

  • Display Format: LCD
  • Back light: LED
  • SPO2:35-99%
  • Pulse Ratio:30-250 BPM
  • Pulse Wave: LCD Graphic Display
  • Battery Voltage Low Indication: LCD signals.
  • Power Requirements: Two AA size 1.5V Alkali Battery;
  • Power Consumption: less than 20 mA.
  • Resolution: ±1% for SPO2 and ±1 BPM for Pulse Ratio.
  • Measurement Accuracy: ±2% in stage of 70% % SPO2 and meaningless when stage being smaller than 70%. ±2BPM for Pulse Ratio.
  • Measurement Performance in Weak Filling Condition : Oxyhemoglobin and pulse & value can be shown correctly when pulse-filling ratio is 0.4%.
  • Interference Resistance Capacity against Ambient Light : Deviation is smaller than ±1% between & value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room.