{"title":"Ivy Biomedical","description":"","products":[{"product_id":"ivy-biomedical-7600-cardiac-trigger","title":"Ivy Biomedical 7600 Cardiac Trigger","description":"\u003cp\u003e \u003c\/p\u003e  \u003cp style=\"text-align:center\"\u003e\u003cspan style=\"font-size:36px\"\u003e\u003cstrong\u003eIvy Biomedical 7600 Cardiac Trigger\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e \u003c\/p\u003e  \u003cp\u003eThis listing is for a fully refurbished Ivy 7600 cardiac trigger. The unit would be covered by a full 1yr warranty.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe Model 7600 is Ivy Biomedical System’s 5th generation cardiac trigger monitor used in applications requiring precision ECG R-wave synchronization for gating host systems on and off. The Model 7600 incorporates an intuitive, menu-driven, touch-screen user interface, simplifying operation for clinicians and technicians.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe Model 7600 is a favorite for use in cardiovascular diagnostic imaging studies, especially in gamma camera, nuclear medicine, and molecular imaging applications.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eWorry Free Operation\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eAcquiring reliable and consistent ECG triggers can often be a challenging task, and selecting the right ECG vector can be problematic. The Model 7600 uses a 4-lead ECG configuration in order to provide automatic lead selection capability. This feature monitors each ECG vector simultaneously, and automatically selects the best ECG lead for triggering, thereby delivering reliable triggering even under challenging or changing patient conditions. Red markers on the ECG waveform indicate when and where triggering occurred for visual verification and assurance.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe Model 7600 offers a compact 6” diagonal color TFT display, ECG simulator, heart rate limit alarms, RS-232 communication interface, multiple factory configured trigger output pulse width and amplitude options, optional integrated strip chart recorder, optional roll stand mount, and more at an affordable price.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003ePrecision Performance\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe Model 7600 offers trigger pulse output performance with less than 2ms of delay, and ±75µs of dither (accuracy), ensuring consistent and reliable triggering.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eRegulatory \u0026amp; Compliance\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eAll Ivy Biomedical products comply with global standards for safety, EMC, quality management, and environmental requirements.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e \u003c\/p\u003e  \u003cp\u003eECG\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eLead Selection:\u003c\/strong\u003e\u003cbr\u003e Trigger Lead: LI, LII, LIII, and AUTO - menu selectable.\u003cbr\u003e Second Lead: LI, LII and LIII – menu selectable.\u003cbr\u003e Patient Cable: 4-lead patient cable with 6-Pin AAMI standard connector.\u003cbr\u003e Isolation: Isolated from ground related circuits by \u0026gt;4 kV rms, 5.5 kV peak\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eElectrode Impedance Measurement\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eTechnique: 10 Hz ac signal \u0026lt; 10 uA rms\u003cbr\u003e Range: 200kO per lead\u003cbr\u003e Accuracy: ±3% ±1kO\u003cbr\u003e Recommended Electrode: 10% Chloride sponge type (Ivy P\/N: 590436)\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eCardiotach\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eRange: 10 to 350 BPM (Pediatric \/ Neonate)\u003cbr\u003e 10 to 300 BPM (Adult)\u003cbr\u003e Accuracy: ±1% ±1 BPM\u003cbr\u003e Resolution: 1 BPM\u003cbr\u003e Sensitivity: 300 µV peak\u003cbr\u003e Tall T Wave Rejection: Rejects T waves = 1.2 * R-wave\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003ePacer Pulse Rejection\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eWidth: 0.1 to 2 ms at ±2 to ±700 mV\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eHigh Rate: 15 to 250 BPM in 5 BPM increments\u003cbr\u003e Low Rate: 10 to 245 BPM in 5 BPM increments\u003cbr\u003e Asystole: R to R interval \u0026gt;6 seconds\u003cbr\u003e Lead Off: Detached lead or offset potential \u0026gt;0.5 V\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eTest Mode\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eInternal: ECG 1 mV\/100 ms referred to input @ 70 BPM\u003cbr\u003e Simulator: ECG waveform amplitude: 1mV\u003cbr\u003e Simulator Range: 10 – 250 BPM.\u003cbr\u003e Simulator Rate: Variable rate in steps of 30, 60, 90, 120, 150, 180, 210 and 240 BPM. Manually adjustable in increments of 1 BPM.\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eActive Matrix TFT Color Touch Screen LCD (640x480)\u003cbr\u003e Screen Size: 13.25cm x 9.94cm, 16.5cm (6.5in) diagonal\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eSize: Height: 7.49in. (19.02cm)\u003cbr\u003e Width: 7.94in. (20.17cm)\u003cbr\u003e Depth: 5.18in. (13.16cm)\u003cbr\u003e Weight: 3.9 lbs. (1.8kg)\u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eRecorder\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eOptional Feature\u003cbr\u003e Writing Method: Direct Thermal\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eSynchronized Output (Trigger)\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eTest input signal at ECG leads: Conditions: ½ sine wave, 60ms width, 1mV amplitude, 1 pulse\/second\u003cbr\u003e Output Trigger Delay: \u0026lt; 10 ms\u003cbr\u003e R to R Trigger Accuracy: ±75 µs typical @ 1 mV input\u003cbr\u003e Pulse width: 100ms\u003cbr\u003e Pulse amplitude: 0 to +5V\u003cbr\u003e Output Impedance: \u0026lt;100 O\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eTemperature Range: 15°C to 40°C\u003cbr\u003e Relative Humidity: 0-90% non-condensing\u003cbr\u003e Altitude: -100 meters to +3,000 meters\u003cbr\u003e Atmospheric Pressure: 500-1060 mbar\u003cbr\u003e Protection against ingress of fluids: IPX1 – Protection against vertically falling drops of water\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eStorage Environment\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eTemperature Range: -20°C to 49°C\u003cbr\u003e Relative Humidity: 0-100%\u003cbr\u003e Altitude: -100 meters to +14,000 meters\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eVoltage Input: 100-120V~; 200-230V~\u003cbr\u003e Line Frequency: 50\/60 Hz\u003cbr\u003e Fuses Type and Rating: T.5A, 250V (Metric 5x20 mm)\u003cbr\u003e Maximum ac Power\u003cbr\u003e Consumption: 45 VA\u003cbr\u003e Power Recovery: Automatic, if power is restored within 30 seconds\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eRegulatory\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eUnit meets or exceeds the specifications for:\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eAAMI Cardiac Monitor Standard EC-13\u003c\/li\u003e \t\u003cli\u003eUL60601-1\u003c\/li\u003e \t\u003cli\u003eCAN\/CSA C22.2 No 601.1-M90\u003c\/li\u003e \t\u003cli\u003eCDN MDR (CMDCAS)\u003c\/li\u003e \t\u003cli\u003eIEC 60601-2-27\u003c\/li\u003e \t\u003cli\u003eMDD.93\/42\/EEC\u003c\/li\u003e \t\u003cli\u003eCE 0413\u003c\/li\u003e \t\u003cli\u003eISO 13485:2003\u003c\/li\u003e \t\u003cli\u003eFDA\/CGMP\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e \u003c\/p\u003e  \u003cp\u003e \u003c\/p\u003e ","brand":"Ivy Biomedical","offers":[{"title":"Default Title","offer_id":46350407598211,"sku":"7600","price":1695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/ivy7600_9225f444-0be4-4b24-8b18-81eace774ff7.jpg?v=1768284043"},{"product_id":"ivy-biomedical-7800-cardiac-trigger","title":"Ivy Biomedical 7800 Cardiac Trigger","description":"\u003cp style=\"text-align:center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:28px\"\u003eIvy Biomedical 7800 Cardiac Trigger\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e \u003c\/p\u003e  \u003cp\u003eThis listing is for a fully refurbished Ivy 7800 cardiac trigger. The unit would be covered by a full 1yr warranty.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe Model 7800 is Ivy Biomedical System’s 5th generation cardiac trigger monitor used in applications requiring precision ECG R-wave synchronization for gating host systems on and off. The Model 7800 incorporates an intuitive, menu-driven, touch-screen user interface, simplifying operation for clinicians and technicians.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe Model 7800 is a favorite for use in cardiovascular diagnostic imaging studies, especially in computed tomography (CT) applications.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eWorry Free Operation\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eAcquiring reliable and consistent ECG triggers can often be a challenging task, and selecting the right ECG vector can be problematic. The Model 7800 uses a 4-lead ECG configuration in order to provide automatic lead selection capability. This feature monitors each ECG vector simultaneously, and automatically selects the best ECG lead for triggering, thereby delivering reliable triggering even under challenging or changing patient conditions. Red markers on the ECG waveform indicate when and where triggering occurred for visual verification and assurance. In addition, an electrode impedance measurement function enables quick verification of proper electrode\/skin preparation prior to patient scans.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe Model 7800 offers a large 8” diagonal color TFT display, ECG simulator, heart rate limit alarms, electrode impedance check, X-ray on signal input, ECG waveform export, Ethernet and RS-232 communication interface, multiple factory configured trigger output pulse width and amplitude options, optional integrated strip chart recorder, optional roll stand mount, and more.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eSeveral system integration features are provided to enable streamlined and automated operation including ECG waveform output to both the gantry display and operator’s console, X-ray on signal input for ECG waveform file capture for each patient scan, and Ethernet communication for remote command and control.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003ePrecision Performance\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe Model 7800 offers trigger pulse output performance with less than 2ms of delay, and ±75µs of dither (accuracy), ensuring consistent and reliable triggering.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eRegulatory \u0026amp; Compliance\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eAll Ivy Biomedical products comply with global standards for safety, EMC, quality management, and environmental requirements.\u003c\/p\u003e  \u003cp\u003e \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eECG\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eLead Selection:\u003c\/strong\u003e\u003cbr\u003e Trigger Lead: LI, LII, LIII, and AUTO - menu selectable.\u003cbr\u003e Second Lead: LI, LII and LIII – menu selectable.\u003cbr\u003e Patient Cable: 4-lead patient cable with 6-Pin AAMI standard connector.\u003cbr\u003e Isolation: Isolated from ground related circuits by \u0026gt;4 kV rms, 5.5 kV peak\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eElectrode Impedance Measurement\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eTechnique: 10 Hz ac signal \u0026lt; 10 uA rms\u003cbr\u003e Range: 200kO per lead\u003cbr\u003e Accuracy: ±3% ±1kO\u003cbr\u003e Recommended Electrode: 10% Chloride sponge type (Ivy P\/N: 590436)\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eCardiotach\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eRange: 10 to 350 BPM (Pediatric \/ Neonate)\u003cbr\u003e 10 to 300 BPM (Adult)\u003cbr\u003e Accuracy: ±1% ±1 BPM\u003cbr\u003e Resolution: 1 BPM\u003cbr\u003e Sensitivity: 300 µV peak\u003cbr\u003e Tall T Wave Rejection: Rejects T waves = 1.2 * R-wave\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003ePacer Pulse Rejection\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eWidth: 0.1 to 2 ms at ±2 to ±700 mV\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eHigh Rate: 15 to 250 BPM in 5 BPM increments\u003cbr\u003e Low Rate: 10 to 245 BPM in 5 BPM increments\u003cbr\u003e Asystole: R to R interval \u0026gt;6 seconds\u003cbr\u003e Lead Off: Detached lead or offset potential \u0026gt;0.5 V\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eTest Mode\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eInternal: ECG 1 mV\/100 ms referred to input @ 70 BPM\u003cbr\u003e Simulator: ECG waveform amplitude: 1mV\u003cbr\u003e Simulator Range: 10 – 250 BPM.\u003cbr\u003e Simulator Rate: Variable rate in steps of 30, 60, 90, 120, 150, 180, 210 and 240 BPM. Manually adjustable in increments of 1 BPM.\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eActive Matrix TFT Color Touch Screen LCD (640x480)\u003cbr\u003e Screen Size: 17.09cm x 12.82cm, 21.36cm (8.4\") diagonal\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eSize: Height: 8.72in. (22.14cm)\u003cbr\u003e Width: 9.25in. (23.50cm)\u003cbr\u003e Depth: 6.10in. (15.49cm)\u003cbr\u003e Weight: 5.6 lbs. (2.54kg)\u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eRecorder\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eOptional Feature\u003cbr\u003e Writing Method: Direct Thermal\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eSynchronized Output (Trigger)\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eTest input signal at ECG leads: Conditions: ½ sine wave, 60ms width, 1mV amplitude, 1 pulse\/second\u003cbr\u003e Output Trigger Delay: \u0026lt; 10 ms\u003cbr\u003e R to R Trigger Accuracy: ±75 µs typical @ 1 mV input\u003cbr\u003e Pulse width: 100ms\u003cbr\u003e Pulse amplitude: 0 to +5V\u003cbr\u003e Output Impedance: \u0026lt;100 O\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eTemperature Range: 15°C to 40°C\u003cbr\u003e Relative Humidity: 0-90% non-condensing\u003cbr\u003e Altitude: -100 meters to +3,000 meters\u003cbr\u003e Atmospheric Pressure: 500-1060 mbar\u003cbr\u003e Protection against ingress of fluids: IPX1 – Protection against vertically falling drops of water\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eStorage Environment\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eTemperature Range: -20°C to 49°C\u003cbr\u003e Relative Humidity: 0-100%\u003cbr\u003e Altitude: -100 meters to +14,000 meters\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eVoltage Input: 100-120V~; 200-230V~\u003cbr\u003e Line Frequency: 50\/60 Hz\u003cbr\u003e Fuses Type and Rating: T.5A, 250V (Metric 5x20 mm)\u003cbr\u003e Maximum ac Power\u003cbr\u003e Consumption: 45 VA\u003cbr\u003e Power Recovery: Automatic, if power is restored within 30 seconds\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eEthernet 10Base-T, IEEE 802.3 (2 Channels)\u003cbr\u003e RS-232\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eUSB Memory Stick\u003cbr\u003e \u003cbr\u003e  \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eRegulatory\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eUnit meets or exceeds the specifications for:\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eAAMI Cardiac Monitor Standard EC-13\u003c\/li\u003e \t\u003cli\u003eUL60601-1\u003c\/li\u003e \t\u003cli\u003eCAN\/CSA C22.2 No 601.1-M90\u003c\/li\u003e \t\u003cli\u003eCDN MDR (CMDCAS)\u003c\/li\u003e \t\u003cli\u003eIEC 60601-2-27\u003c\/li\u003e \t\u003cli\u003eMDD.93\/42\/EEC\u003c\/li\u003e \t\u003cli\u003eCE 0413\u003c\/li\u003e \t\u003cli\u003eISO 13485:2003\u003c\/li\u003e \t\u003cli\u003eFDA\/CGMP\u003c\/li\u003e \u003c\/ul\u003e ","brand":"Ivy Biomedical","offers":[{"title":"Default Title","offer_id":46350407630979,"sku":"7800","price":1695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/IVY_7800_30e29da2-6aa2-4bea-947d-f519678d708d.jpg?v=1768284042"},{"product_id":"ivy-biomedical-dl36-03-3","title":"ivy biomedical+DL36-03+3","description":"\u003cp\u003e  \tï»\u003c\/p\u003e  \u003cp\u003e  \t\u003cspan\u003eDiscount Cardiology is your best resource for Replacement EKG patient cables, ECG patient cables, ECG Leadwires, EKG leadwires, leadwire trunk cables, holter cables, resting ecg cables, stress test cables with snap ends, patient monitoring cables, Pulse oximetry cables, SPO2 Finger probes, Pulse oximeter sensor, leadwire sets, acquisition module, 3 lead patient cables, 5 lead patient cabels, 7 lead patient cables, 10 lead patient cables and 12 lead patient cables. Discount Cardiology carries all the major brands at the lowest prices including: Bionet, Brentwood \/ Midmark, Burdick, Cardiac Science, Cardioline, CardioTech, Commwell medical, Contec, Daily Care, Dr. Lee, Edan Instruments, cardiologyforless, EKG, Fukuda Denshi, Futuremed, G. E. Healthcare, Midmark, Mortara, Nasiff Associates, Nihon Kohden, Norav, Philips, QRS, Quinton, Schiller, Welch Allyn \/ Tycos, Kenz, MIR, Nellcor, Masimo, BCI, Datascope, Siemens, Mindray, HP, Zoll, Ambu, Kendall, Covidian , Venni, Spacelabs, Criticare, and many more. We sell replacement ECG cables and SPO2 sensors at the lowest prices, have a large inventory, and have been in the business over 25 years! Please feel free to contact Discount Cardiology for all of your \u003ca href=\"Patient-Cables-and-Leads\/\"\u003eEKG\/ECG patient cable needs\u003c\/a\u003e.  We also sell \u003ca href=\"EKG-Paper\/\"\u003eEKG\/ECG Chart Paper\u003c\/a\u003e and \u003ca href=\"Electrodes\/\"\u003eEKG\/ECG electrodes\u003c\/a\u003e at the lowest prices. \u003c\/span\u003e\u003cspan\u003eDiscount Cardiology is one of the largest wholesalers of \u003ca href=\"EKG-Machines\/\" title=\"EKG \/ ECG machines\"\u003e\u003cstrong\u003eEKG \/ ECG machines\u003c\/strong\u003e\u003c\/a\u003e, \u003ca href=\"Defibrillators-and-AED\/\"\u003eDefibrillators\/AEDs\u003c\/a\u003e, Holter Systems, \u003ca href=\"Spirometers\/\" title=\"Spirometers\"\u003e\u003cstrong\u003eSpirometers\u003c\/strong\u003e\u003c\/a\u003e, \u003ca href=\"EECP-Machines-ECP\/\"\u003eEECP Machines\u003c\/a\u003e, \u003ca href=\"Diagnostic-Ultrasound\/\"\u003eUltrasound machines\u003c\/a\u003e, \u003ca href=\"Pulse-Oximeters\/\"\u003ePulse oximeters\u003c\/a\u003e, \u003ca href=\"Dopplers\/\"\u003eVascular Dopplers\u003c\/a\u003e, \u003ca href=\"Telemetry\/\"\u003eCardiac Rehab Telemetry systems\u003c\/a\u003e and \u003ca href=\"Stress-Systems\/\"\u003eStress testing treadmill systems\u003c\/a\u003e. Discount Cardiology also provides Medical Equipment repair services for out-of-warranty equipment, the rental of EKG machines, and the sale of new, refurbished, and \u003ca href=\"Certified-Pre-Owned\/\"\u003ecertified pre-owned medical equipment\u003c\/a\u003e.WE WILL BEAT ANY PRICE IN THE COUNTRY!  800-507-8244\u003cbr\u003e  \t\u003c\/span\u003e\u003c\/p\u003e  ","brand":"Ivy Biomedical","offers":[{"title":"Default Title","offer_id":46350407729283,"sku":"DL36-03","price":0.0,"currency_code":"USD","in_stock":true}]}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/collections\/Ivy-Biomedical-Medical-Equipment.png?v=1768885374","url":"https:\/\/discountcardiology.com\/collections\/ivy-biomedical.oembed","provider":"Discount Cardiology","version":"1.0","type":"link"}