{"product_id":"burdick-280-ekg-machine","title":"Burdick  280 EKG Machine","description":"\u003cp style=\"text-align:center\"\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cu\u003e\u003cstrong\u003eBurdick 280 EKG Machine\u003c\/strong\u003e\u003c\/u\u003e\u003c\/span\u003e\u003c\/p\u003e  \u003cp style=\"text-align:center\"\u003eThis listing is for a fully refurbished unit with accessories and a 1yr warranty. The unit would arrive \"patient ready\"\u003c\/p\u003e  \u003cdiv class=\"csc-header csc-header-n1\"\u003e \u003ch2\u003eSummary\u003c\/h2\u003e  \u003cp\u003eThe Burdick ELI 280 (12-lead resting ECG) represents a feature-rich, clinically advanced ECG system suited to high‐volume environments in both hospital and outpatient settings. With its large touchscreen display, advanced signal fidelity, automated Best10 quality capture, wireless\/ wired acquisition flexibility, network connectivity, and interpretive algorithm, it offers a strong workflow and clinical offering. For organizations needing quality ECG diagnostics with integration into digital health systems, this unit stands out.\u003c\/p\u003e  \u003chr\u003e \u003ch2\u003ePhysical \u0026amp; Hardware Specifications\u003c\/h2\u003e  \u003ch3\u003eDisplay \u0026amp; User Interface\u003c\/h3\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eIt features a \u003cstrong\u003e10.1” high-resolution colour touchscreen LCD\u003c\/strong\u003e for display of up to 12 leads simultaneously. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eThe screen layout is “widescreen” to permit full-lead display, menu navigation, fast patient data entry and clear verification of electrode connections. \u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003ch3\u003eSize, Weight, and Portability\u003c\/h3\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eOne source gives the device weight as \u003cstrong\u003e12.5 lbs (5.68 kg) including battery (without paper)\u003c\/strong\u003e. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eDimensions given: 17.5 × 15.5 × 4.5 inches (≈ 44.45 × 39.37 × 11.43 cm) in one spec sheet. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eThe device includes an internal rechargeable battery (in addition to universal AC power supply) in many configurations. \u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003ch3\u003ePrinting \u0026amp; Storage\u003c\/h3\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eThermal printer included: options for paper perforated Z-fold, either A4 or 8.5 × 11″ wide; printer speeds 5, 10, 25, or 50 mm\/s; gain settings 5, 10, or 20 mm\/mV. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eInternal storage: up to \u003cstrong\u003e200 ECGs\u003c\/strong\u003e in memory in certain configurations. \u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003ch3\u003ePerformance \/ Signal Acquisition Details\u003c\/h3\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eA\/D conversion: 20 bits resolution (≈ 1.17 µV LSB) in one spec sheet. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eFrequency response: 0.05 to 300 Hz; filters include high-performance baseline filter, AC interference filter (50\/60 Hz), low-pass filters at 40 Hz, 150 Hz or 300 Hz. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eDigital sampling: The spec sheet lists \u003cstrong\u003e40,000 samples\/second\/channel\u003c\/strong\u003e for pacemaker spike detection and \u003cstrong\u003e1,000 samples\/second\/channel\u003c\/strong\u003e for recording\/analysis. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eInput impedance, electrode offset tolerance, common-mode rejection, patient leakage \/ chassis leakage meet ANSI\/AAMI standards (e.g., EC11, ES1) in one spec sheet. \u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003chr\u003e \u003ch2\u003eECG Acquisition \u0026amp; Processing Capabilities\u003c\/h2\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eThe system supports full 12-lead resting ECG acquisition.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eThe “Best 10” feature: The device evaluates signal quality\/noise and selects the best contiguous 10 second interval from up to 5 minutes of acquired data, reducing need for repeat ECGs due to artifact.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eHook-up verification and lead reversal detection: The system detects lead reversals (claim: up to 80% of lead reversals can be detected with a false positive rate of 1.4%). \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003ePacemaker spike detection supported (enabled by high sampling) for reliable capture of pacing spikes. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eThe print formats: options include 12-lead print (10 s of 12 leads), 3+1 (2.5 s of 12 leads in 3-channel format + 10 s rhythm strip of 1 lead), 3+3, 6, 6+6. \u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003chr\u003e \u003ch2\u003eWorkflow, Connectivity \u0026amp; Integration\u003c\/h2\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eConnectivity: Offers network connectivity for EMR\/EHR, PACS or CVIS integration. Several sources mention USB, LAN, 802.11 wireless options. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eAcquisition module choice: Either the wireless acquisition module (WAM) or a wired acquisition module (AM12). Both include replaceable lead wires, lead fail indicator, and remote control buttons for ECG acquisition and rhythm printing. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eData security: Supports device access controls, LDAP\/Active Directory integration, encryption at rest and in transit for ePHI. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eDesigned for high‐volume ECG workflows: The large screen, quick patient data entry, and full-lead verification aim to reduce repeat studies and increase throughput. \u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003chr\u003e \u003ch2\u003eInterpretive \/ Clinical Algorithm Capabilities\u003c\/h2\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eThe device includes (or optionally can include) the VERITAS® resting ECG interpretation algorithm (from Mortara) which uses gender-specific, adult and pediatric criteria to provide a preliminary interpretation (to be confirmed by a clinician). \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eHook-up confirmation and detection of lead reversals are part of the interpretive workflow. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eThe high sampling rate (40,000 sps\/channel) supports accurate pacemaker spike detection, which is clinically relevant for patients with pacing devices. \u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003chr\u003e \u003ch2\u003eUsability, Maintenance \u0026amp; Other System Aspects\u003c\/h2\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eThe touchscreen UI and full-lead display make it more intuitive for operators and reduce risk of mis-lead placement or misinterpretation.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eThe replaceable lead wires and modular acquisition options increase serviceability.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eThermal printing and internal ECG storage allow for on-site review and archiving; however, facilities may still need to manage paper supply, storage space for printed ECGs, and digital export.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eBecause of network integration and data encryption features, it is suitable for facilities needing to comply with data security \/ HIPAA \/ ePHI requirements.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eMaintenance: As with any diagnostic ECG system, calibration, lead wire integrity checks, electrode compatibility, and compliance with safety standards (e.g., ANSI\/AAMI) remain important. The user manual emphasises safety, correct AC power connection (hospital grade outlet), and patient isolation distances. \u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003chr\u003e \u003ch2\u003eStrengths \u0026amp; Potential Limitations\u003c\/h2\u003e  \u003ch3\u003eStrengths\u003c\/h3\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eVersatility and workflow optimization: The Best 10 feature, large touchscreen, full 12-lead display, and lead-verification features help reduce repeats and operator error.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eFlexible acquisition: Wired or wireless options allow adaptation to bedside, portable or isolation settings.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eSolid connectivity\/integration: Designed for modern networked workflow, EMR\/EHR integration, and supports data security features.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eHigh technical signal fidelity: High sampling rate, broad frequency response, 20-bit A\/D contribute to accurate ECG signal capture (including pacemaker spikes).\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eRecognised interpretive algorithm: The VERITAS algorithm adds clinical decision support (though always confirmed by clinician).\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eProven product lineage: From Mortara\/Burdick\/Welch Allyn heritage, meaning good service network and known track record.\u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003ch3\u003ePotential Limitations \/ Considerations\u003c\/h3\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eAs a feature-rich ECG machine, cost is higher than basic ECG units; specifications suggest mid\/high end pricing.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eThe device weight (12.5 lb) is moderate for portability but not ultra-light.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eWhile 200 ECG storage is adequate for most practices, larger facilities may need bigger archival solutions or network digital storage.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eWireless acquisition module adds freedom but also complexity (battery life, wireless reliability, troubleshooting) relative to fully wired units.\u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eAs with all automated interpretation, the algorithm is a preliminary tool and must be reviewed by a trained clinician; over-reliance may lead to errors if not used correctly.\u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e  \u003chr\u003e \u003ch2\u003e \u003c\/h2\u003e  \u003ch2\u003eBackground and Positioning\u003c\/h2\u003e  \u003cul\u003e \t\u003cli\u003e \t\u003cp\u003eThe device is branded as the ELI 280 Resting Electrocardiograph and is part of the cardiology-diagnostic portfolio of Hillrom (formerly Welch Allyn \/ Mortara \/ Burdick) under the parent company Baxter International. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eIt is targeted at facilities requiring \u003cstrong\u003ehigh-volume ECG workflows\u003c\/strong\u003e, from physician offices to hospital acute care settings.. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eIt supports both wired and wireless acquisition modules, making it versatile for bedside, isolation, or mobile use. \u003c\/p\u003e \t\u003c\/li\u003e \t\u003cli\u003e \t\u003cp\u003eIn short: a mature, feature-rich 12-lead resting ECG system designed for clinical\/diagnostic print, storage, and network integration.\u003c\/p\u003e \t\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e ","brand":"Burdick","offers":[{"title":"Default Title","offer_id":46350324334723,"sku":"BUR-280","price":2695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/burdick_280_cc3d5fec-35bb-459f-88ee-5ebdd74ca291.jpg?v=1768283495","url":"https:\/\/discountcardiology.com\/products\/burdick-280-ekg-machine","provider":"Discount Cardiology","version":"1.0","type":"link"}