{"product_id":"carefusion-micro-i-spirometer","title":"CAREFUSION MICRO I SPIROMETER","description":"\u003cp\u003e \u003c\/p\u003e    \u003cp\u003e \u003c\/p\u003e    \u003ch1 style=\"text-align: center;\"\u003e\u003cspan style=\"font-size:48px\"\u003e\u003cstrong\u003eMicro I\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e    \u003cp\u003eObtain handheld spirometry\u003c\/p\u003e    \u003cdiv\u003e  \u003cp\u003eThe Micro I handheld spirometer with high-definition backlit display measures and displays the patient's forced vital capacity. Its portability ideally supports general and private medical practices, outpatient departments, occupational health settings, and heart and lung transplantation units.\u003c\/p\u003e  \u003c\/div\u003e    \u003cp\u003e \u003c\/p\u003e    \u003cp\u003e\u003cstrong\u003eRelevant index display\u003c\/strong\u003e\u003c\/p\u003e    \u003cp\u003eThe device measures FEV1, FVC, FEV6, PEF, FEV1\/FVC, FEV1\/FEV6 and F25-75 ratios.\u003c\/p\u003e    \u003cp\u003e\u003cstrong\u003eCompliance modes\u003c\/strong\u003e\u003c\/p\u003e    \u003cp\u003eThe device provides ATS\/ERS 2005 quality prompts for each maneuver, and NLHEP configuration mode.\u003c\/p\u003e    \u003cp\u003e \u003c\/p\u003e    \u003cp\u003e\u003cstrong\u003eViewing options\u003c\/strong\u003e\u003c\/p\u003e    \u003cp\u003eYou can view the current or best manuever with predicted value displayed as either % predicted or z score.\u003c\/p\u003e    \u003cp\u003e\u003cstrong\u003eDevice verification\u003c\/strong\u003e\u003c\/p\u003e    \u003cp\u003eThe spirometer provides a calibration check to verify the device.\u003c\/p\u003e    \u003cp\u003e\u003cstrong\u003eDevice configuration\u003c\/strong\u003e\u003c\/p\u003e    \u003cp\u003ePC software helps configure the device.\u003c\/p\u003e    \u003cp\u003e\u003cstrong\u003eBattery recharging\u003c\/strong\u003e\u003c\/p\u003e    \u003cp\u003eThe spirometer comes with a rechargeable battery and charger in the carrying case.\u003c\/p\u003e    \u003cp\u003e \u003c\/p\u003e    \u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" style=\"width:322px\"\u003e  \t\u003cthead\u003e  \t\t\u003ctr\u003e  \t\t\t\u003cth colspan=\"2\"\u003e  \t\t\t\u003cp\u003e\u003cstrong\u003eMicro I\u003c\/strong\u003e\u003c\/p\u003e  \t\t\t\u003c\/th\u003e  \t\t\u003c\/tr\u003e  \t\u003c\/thead\u003e  \t\u003ctbody\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd colspan=\"2\"\u003e  \t\t\t\u003cp\u003e\u003cstrong\u003eMeasurements\u003c\/strong\u003e\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e \u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eFEV1, FEV6, FVC, FEV1\/FEV6, FEV1\/FVC, PEF, FEF25-75, FEF75, FEF25\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eVolume range:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e0.1–8 L \u003cem\u003e(gold standard turbine 0.1–9.99 L)\u003c\/em\u003e\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eFlow range:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e0.2–15 L\/s\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eAccuracy:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e±3% to ATS recommendations\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eDisplay:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e128 px x 128 px graphic backlit monochrome LCDm\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eBattery life:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eApproximately 30 h with a fully charged battery\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003ePower supply:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eInput: 100–240 VAC 50–60 Hz 0.5A\u003cbr\u003e  \t\t\tOutput: 5 V 1.2 A\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eDimensions:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e6.4\" x 2.4\" x 1.2\" \u003cem\u003e(162 cm x 61 cm x 30 cm)\u003c\/em\u003e\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eWeight:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e0.33 lb \u003cem\u003e(152 g)\u003c\/em\u003e\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eOperating temperature:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eThe instrument operates in a uniform environment of 10–35 °C, out of direct sunlight\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eOperating humidity:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e20–80% RH\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eStorage temperature:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e-20–+70 °C\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eStorage humidity:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e30–90% RH\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eRequirements:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eAn IBM-compatible PC, with hardware that meets or exceeds the following minimum requirements:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd colspan=\"2\"\u003e  \t\t\t\u003cp\u003e\u003cstrong\u003ePC configuration\u003c\/strong\u003e\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eProcessor:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e800 MHz or more\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eRAM:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e256 MB\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eFree disk space:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003e50 MB\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eUSB port:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eAt least one free\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eOperating system:\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\u003cp\u003eWindows\u003csup\u003e®\u003c\/sup\u003e XP, Windows Vista 32 bit, Windows Vista 64 bit, Windows Server 2003 or Windows Server 2008\u003c\/p\u003e  \t\t\t\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\u003c\/tbody\u003e  \u003c\/table\u003e  ","brand":"CAREFUSION","offers":[{"title":"Default Title","offer_id":46350335672451,"sku":"MICRO I","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/discountcardiology.com\/products\/carefusion-micro-i-spirometer","provider":"Discount Cardiology","version":"1.0","type":"link"}