{"product_id":"masimo-lnop-neo-l-oximeter-sensor","title":"Masimo LNOP Neo L Oximeter Sensor","description":"\u003cp style=\"text-align: center;\"\u003e  \t\u003cspan style=\"font-size:16px;\"\u003e\u003cu\u003e\u003cstrong\u003eMasimo 1002 LNOP Neo Neonatal Spo2 sensor\u003c\/strong\u003e\u003c\/u\u003e\u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e  \tFaster Detection of Oxygen Saturation Changes with a Single-Patient-Use Sensor Designed for the Ear Concha\u003c\/p\u003e  \u003cp\u003e  \tWhile Masimo SET Measure-through Motion and Low Perfusion pulse oximetry overcomes the limitations of conventional pulse oximetry and offers 97% sensitivity and 95% specificity for alarms during motion and low perfusion conditions, there are still some advantages to monitoring on the head such as faster response to oxygenation changes during low perfusion and the use of an alternative site when the digit is unavailable.\u003c\/p\u003e  \u003cp\u003e  \tAs a single-patient-use ear sensor that is placed securely in the cavum conchae (the deep hollow near the ear canal opening), the E1 allows clinicians to combine Masimo SET performance with a reliable alternative monitoring site while minimizing cross-contamination.\u003c\/p\u003e  \u003cp\u003e  \t \u003c\/p\u003e  \u003ctable\u003e  \t\u003ctbody\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t \u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t\u003cstrong\u003eNeonatal\u003c\/strong\u003e\n\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t\u003cstrong\u003ePediatric\u003c\/strong\u003e\n\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t\u003cstrong\u003eAdult\u003c\/strong\u003e\n\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\tSofTouch Sensors\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\tLNOP\u003csup\u003e®\u003c\/sup\u003e NeoPt-L\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\tLNOP\u003csup\u003e®\u003c\/sup\u003e Y-\u003cu\u003eI\u003c\/u\u003e Multisite\u003cbr\u003e  \t\t\t\t\u003cu\u003e \u003c\/u\u003eLNCS\u003csup\u003e®\u003c\/sup\u003e Y-\u003cu\u003eI\u003c\/u\u003e Multisite\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\tLNOP\u003csup\u003e®\u003c\/sup\u003e Y-\u003cu\u003eI\u003c\/u\u003e Multisite\u003cbr\u003e  \t\t\t\t\u003cu\u003e \u003c\/u\u003eLNCS\u003csup\u003e®\u003c\/sup\u003e Y-\u003cu\u003eI\u003c\/u\u003e Multisite\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t \u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\tLNOP\u003csup\u003e®\u003c\/sup\u003e Newborn\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t \u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\tLNCS\u003csup\u003e®\u003c\/sup\u003e NeoPt\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t \u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\tLNOP\u003csup\u003e®\u003c\/sup\u003e Y-\u003cu\u003eI\u003c\/u\u003e Multisite\u003cbr\u003e  \t\t\t\t\u003cu\u003e \u003c\/u\u003eLNCS\u003csup\u003e®\u003c\/sup\u003e Y-\u003cu\u003eI\u003c\/u\u003e Multisite\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\u003c\/tbody\u003e  \u003c\/table\u003e  \u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" class=\"MsoNormalTable\" style=\"width:6.25in\" width=\"600\"\u003e  \t\u003ctbody\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t \u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t\u003cstrong\u003eNeonatal \u003c\/strong\u003e\n\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t\u003cstrong\u003ePediatric\u003c\/strong\u003e\n\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t\u003cstrong\u003eAdult\u003c\/strong\u003e\n\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\t\u003ctr\u003e  \t\t\t\u003ctd\u003e  \t\t\t\tLNOP Multisite Sensors\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t\u003ca href=\"http:\/\/www.masimo.com\/sensors\/LNOP-YI-CleanShield.htm\"\u003eLNOP\u003csup\u003e®\u003c\/sup\u003e Y-I\u003cbr\u003e  \t\t\t\tw\/ CleanShield Wrap \u003c\/a\u003e\n\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t\u003ca href=\"http:\/\/www.masimo.com\/sensors\/LNOP-YI-Standard.htm\"\u003eLNOP\u003csup\u003e®\u003c\/sup\u003e Y-I\u003cbr\u003e  \t\t\t\tw\/ Standard Wrap \u003c\/a\u003e\n\u003c\/td\u003e  \t\t\t\u003ctd\u003e  \t\t\t\t\u003ca href=\"http:\/\/www.masimo.com\/sensors\/LNOP-YI-Standard-Petite.htm\"\u003eLNOP\u003csup\u003e®\u003c\/sup\u003e Y-I\u003cbr\u003e  \t\t\t\tw\/ Standard Petite Wrap \u003c\/a\u003e\n\u003c\/td\u003e  \t\t\u003c\/tr\u003e  \t\u003c\/tbody\u003e  \u003c\/table\u003e  \u003cp\u003e  \t\u003cstrong\u003eMasimo Reusable Sensors\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e  \tMasimo reusable sensors are designed for performance and durability where ever they are used. Only Masimo sensors can deliver Masimo SET performance, recognized around the world as the leading pulse oximeter technology.\u003c\/p\u003e  \u003cp\u003e  \tMasimo Adhesive Sensors Improve Performance While Reducing Cost\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tAdhesive sensors have always had clinical advantages over reusable 'finger clip' sensors, which have made them the optimal clinical choice of caregivers.\u003c\/li\u003e  \t\u003cli\u003e  \t\tThe risk of cross contamination is less likely from single-patient use adhesive sensors than from reusable sensors.\u003c\/li\u003e  \t\u003cli\u003e  \t\tFor patients who are active or agitated, it is more difficult to shake off an adhesive sensor, thereby making monitoring in high motion environments more effective.\u003c\/li\u003e  \t\u003cli\u003e  \t\tCompared to reusable sensors, adhesive sensors, which decrease pressure on the monitoring site, are less prone to cause pressure necrosis.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \t\u003cb\u003eAdvantages of Single-Patient-Use versus Reusable Sensors\u003c\/b\u003e\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tAvoids cross-contamination risks\u003c\/li\u003e  \t\u003cli\u003e  \t\tReduces complexity of reusable ear sensor management (cleaning, storage, and inter-departmental transport)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \t\u003cb\u003eAdvantages of Head versus Digit Monitoring\u003c\/b\u003e\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tFaster detection of desaturation \/ resaturation compared to digit sensors during low perfusion\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e  \t\u003cli\u003e  \t\tAlternate monitoring site with easy access during surgery, resuscitation, in patients with finger deformities, or when digit access is not possible\u003c\/li\u003e  \t\u003cli\u003e  \t\tOffers reliable measurements during extremely low perfusion when Masimo Max\u003csup\u003e™\u003c\/sup\u003e Sensitivity setting is not enabled\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/li\u003e  \t\u003cli\u003e  \t\tAllows for hands-free monitoring\u003c\/li\u003e  \t\u003cli\u003e  \t\tEar site may offer advantages for pleth variability (PVI\u003csup\u003e®\u003c\/sup\u003e) monitoring to help clinicians assess fluid responsiveness\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \t\u003cb\u003eAdvantages of Ear versus Forehead Monitoring\u003c\/b\u003e\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tAlleviates known accuracy limitations of forehead sensors including venous pulsations and when patients are in a supine or Trendelenburg position\u003csup\u003e2,5\u003c\/sup\u003e\n\u003c\/li\u003e  \t\u003cli\u003e  \t\tProvides alternative to digit sensor when forehead site is unavailable (brain function monitoring, cerebral oxygenation monitoring, or neck stabilization during trauma)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \t\u003cb\u003eAdvantages of Cavum Conchae versus Ear Lobe Monitoring\u003c\/b\u003e\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tStays in place more securely than traditional clip-style sensors on ear lobe\u003c\/li\u003e  \t\u003cli\u003e  \t\tSensor location offers better perfusion than ear lobe for improved signal quality\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \t\u003cb\u003eNewborn Sensors\u003c\/b\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cstrong\u003eProvides the fastest response time and maximum sensitivity, allowing immediate support for newborn resuscitation—when accurate SpO\u003csub\u003e2\u003c\/sub\u003e monitoring is critical.\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tWhen connected to a Masimo SET\u003csup\u003e®\u003c\/sup\u003e-enabled monitor, Newborn sensors immediately and automatically configure the device for fastest response time and highest sensitivity.\u003c\/li\u003e  \t\u003cli\u003e  \t\tFast response Newborn sensors together with Masimo SET\u003csup\u003e®\u003c\/sup\u003e technology deliver critically accurate data instantly.\u003c\/li\u003e  \t\u003cli\u003e  \t\tQuick and easy application and repositioning of sensor with a VelAid\u003csup\u003e™\u003c\/sup\u003e SofTouch\u003csup\u003e™\u003c\/sup\u003e hook and loop attachment strip, allowing for fast and secure application to the newborn skin—even when wet.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \t\"Time is crucial when infants are struggling for life. Masimo's Newborn sensor helps clinicians maximize the time we can spend caring for patients. During newborn resuscitation, frequently other oximeters don't work. With Masimo, we have been able to successfully track newborn resuscitation.\"\u003c\/p\u003e  \u003cp\u003e  \t- Dr. Mitchell Goldstein\u003cbr\u003e  \tPomona Valley Hospital Medical Center\u003cbr\u003e  \tin Pomona, California\u003c\/p\u003e  \u003cp\u003e  \t\"During resuscitation, it is beneficial to have minimal averaging of the SpO\u003csub\u003e2\u003c\/sub\u003e values coupled with maximal sensitivity, and one manufacturer has developed a probe that, when connected, can reprogram the oximeter to function in this manner.\"\u003c\/p\u003e  \u003cp\u003e  \t- Dr. Neil N. Finer\u003cbr\u003e  \tNeoReviews Vol.6 No.4 April 2005\u003c\/p\u003e  \u003cp\u003e  \tAccurate monitoring of a newborn's SpO\u003csub\u003e2\u003c\/sub\u003e during the first seconds of life is critical. The American Academy of Pediatrics' 2005 Neonatal Resuscitation Protocol for pre-term infants recommends using a blend of air and oxygen for resuscitation and a pulse oximeter for monitoring oxygenation. However, it can be challenging to obtain accurate SpO\u003csub\u003e2\u003c\/sub\u003e measurements because the newborn is damp, and often shivering, crying and poorly perfused.\u003c\/p\u003e  \u003cp\u003e  \tThe Newborn Sensor, combined with Masimo SET\u003csup\u003e®\u003c\/sup\u003e or Masimo rainbow SET\u003csup\u003e®\u003c\/sup\u003e technology, gives clinicians the high levels of sensitivity and specificity needed to provide accurate SpO\u003csub\u003e2\u003c\/sub\u003e readings during these challenging conditions. When connected to Masimo oximeters and patient monitors equipped with Masimo SET\u003csup\u003e®\u003c\/sup\u003e, this innovative sensor immediately enables the fastest response time and maximum sensitivity. The sensor's VelAid hook-and-loop attachment strip and adhesive emitter and detector strip allows quick application and stays secure even when the site is wet.\u003c\/p\u003e  \u003cp\u003e  \tNewborn Sensors allow the clinician to focus their attention on their patients instead of using valuable seconds trying to configure instruments and select an appropriately matched sensor to achieve the most accurate readings possible. The fast response Newborn Sensors together with Masimo SET\u003csup\u003e®\u003c\/sup\u003e deliver critically accurate data instantly.\u003c\/p\u003e  \u003cp\u003e  \t\u003cstrong\u003eTrauma Sensor\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cstrong\u003eThe highest resolution, most accurate and rapid SpO\u003csub\u003e2\u003c\/sub\u003e and Pulse Rate measurements when they matter most.\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tA sensor specifically designed to provide immediate support for emergent resuscitation interventions in pediatrics and adults when time is critical.\u003c\/li\u003e  \t\u003cli\u003e  \t\tProvides the fastest response times (lowest averaging) and highest sensitivity on Masimo SET\u003csup\u003e®\u003c\/sup\u003e oximeters and multiparameter monitors equipped with Masimo SET\u003csup\u003e®\u003c\/sup\u003e Oximetry.\u003c\/li\u003e  \t\u003cli\u003e  \t\tEnables clinicians to focus complete attention to addressing the needs of their patients. Valuable seconds are preserved for patient care, not monitor configuration.\u003c\/li\u003e  \t\u003cli\u003e  \t\tVelAid\u003csup\u003e™\u003c\/sup\u003e SofTouch\u003csup\u003e™\u003c\/sup\u003e design allows for quick and easy application and repositioning of sensor with hook and loop attachment strip—stays secure even when site is wet.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \t\"During resuscitation, it is beneficial to have minimal averaging of the SpO\u003csub\u003e2\u003c\/sub\u003e values coupled with maximal sensitivity, and one manufacturer has developed a probe that, when connected, can reprogram the oximeter to function in this manner (Masimo Corp. Irvine, California).\"\u003c\/p\u003e  \u003cp\u003e  \t- Dr. Neil N. Finer\u003cbr\u003e  \tNeoReviews Vol.6 No.4 April 2005\u003c\/p\u003e  \u003cp\u003e  \tMonitoring oxygen staturation through pulse oximetry is a standard of care in trauma settings, such as the emergency room. These devices help to prevent the critical loss of time.\u003c\/p\u003e  \u003cp\u003e  \tThe Trauma Sensor, combined with Masimo SET\u003csup\u003e®\u003c\/sup\u003e or Masimo rainbow SET\u003csup\u003e®\u003c\/sup\u003e technology, gives clinicians the high levels of sensitivity and specificity needed to provide accurate SpO\u003csub\u003e2\u003c\/sub\u003e readings during these challenging conditions. When connected to Masimo oximeters and patient monitors equipped with Masimo SET\u003csup\u003e®\u003c\/sup\u003e, this innovative sensor immediately enables the fastest response time and maximum sensitivity. The sensor's VelAid hook-and-loop attachment strip and adhesive emitter and detector strip allows quick application and stays secure even when the site is wet.\u003c\/p\u003e  \u003cp\u003e  \tThe Trauma Sensor allows the clinician to focus their attention on their patients instead of using valuable seconds trying to configure instruments and select an appropriately matched sensor to achieve the most accurate readings possible. The fast response Trauma Sensor together with Masimo SET\u003csup\u003e®\u003c\/sup\u003e delivers critically accurate data instantly.\u003c\/p\u003e  \u003cp\u003e  \t\u003cstrong\u003eMasimo Blue\u003csup\u003e®\u003c\/sup\u003e Sensors\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cstrong\u003eA breakthrough sensor specifically designed for cyanotic infants and children with congenital heart disease\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tSpecifically for cyanotic neonates, infants and children with congenital heart disease (CHD), the sensor is designed exclusively to maximize accuracy in this vulnerable patient population\u003c\/li\u003e  \t\u003cli\u003e  \t\tProven accurate on cyanotic patients with oxygen saturations as low as 60%\u003csup\u003e6\u003c\/sup\u003e\n\u003c\/li\u003e  \t\u003cli\u003e  \t\tMaximum SpO2 accuracy and reliability allows better management of cardiac medications and ventilation therapy\u003csup\u003e6\u003c\/sup\u003e\n\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \tObtaining accurate and reliable SpO2 measurements on pediatric patients with congenital heart disease has frequently been impossible. This has affected clinicians’ ability to rely on continuous SpO2 measurements to provide care for these patients.\u003c\/p\u003e  \u003cp\u003e  \tAfter extensive research and development, Masimo introduced the Blue sensor, the first pulse oximetry sensor designed specifically for cyanotic neonates, infants, and children. The Masimo Blue sensor is proven accurate to saturations as low as 60%.\u003c\/p\u003e  \u003cp\u003e  \tThe Masimo Blue sensor provides reliable, continuous pulse oximetry that clinicians need to better manage cardiac medications and ventilation therapy of these critical patients.\u003c\/p\u003e  ","brand":"Masimo","offers":[{"title":"Default Title","offer_id":46350419755139,"sku":"MAS-LNOP-NeoL","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/Masimo-LNOP-Neo-L-Oximeter-Sensor-01_be45f738-cade-4ba7-9e96-3168ac7c1419.jpg?v=1768284095","url":"https:\/\/discountcardiology.com\/products\/masimo-lnop-neo-l-oximeter-sensor","provider":"Discount Cardiology","version":"1.0","type":"link"}