Description
Features:
- Super ability in against electrosurgical interference. Neither in cutting nor in burning, ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.
- Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only nasal tube respiration can detect the right respiration waveform and respiration rate).
- 15’’ color TFT LCD screen, High brightness,Wide viewing, 12 waveforms can be displayed on the same screen. Lightness and volume are adjustable independently.
- Streamlined outline design with sense of the times & foldable handle. Multi-language interface selection: Chinese, English, Spanish, Portuguese, French, Arabic, Russian, Italian, Turkish, etc.
- User-friendly and man-machine dialogue interface with pop-up menus, dialogue boxes, rotary mouse and etc.
- Low-power consumption design with standby mode, rechargeable high-energy built-in battery.
- Blood pressure measurement fast and accuratly, with venipuncture function.
- Advanced digital technology, accurately measure SpO2 in low perfusion situation.
- Drug calculation, ST-segment detection
- Display format include OxyCRG diagram, 7-lead ECG waveform, big-font mode simultaneously; can store 5 kinds of user-defined display format
- Sound and light integrated alarm, Alarm parameters can be adjusted to upper or lower.
- Applications in bedside and delivery monitoring; Widely used in patient room, emergency room, operation room, PACU, ICU, CCU, etc.
- WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible.
Technical Specifications:
ECG
- Lead output: 3 wires/5 wires ECG cable
- Lead section: I, II, III, aVR, aVL, aVF, V
- Gain selection: ×1/4, ×1/2, ×1, ×2, ×4 and automatic
- Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s
- Heart rate range: 15-300bpm
- ECG calibration: ± 1 mv
Heart rate accuracy: ± 1%
NIBP
- Philosophy: Oscillometric method
- Measurement type: adult, pediatric, neonate
- Measurement parameter: Systolic, Diastolic, Mean
- Measurement method: manual, automatic, continuous measurement
- Unit: mmHg/kPa selectable
- Accuracy: ±2 or 3mmHg
SpO2
- Display type: Waveform, data
- Measurement range: 0~100%
- Resolution: 1 BPM
- Pulse rate range: 30~250bpm
- Accuracy: ±1bpm
Temperature
- Number of channel: 2 channels, measure surface and cavity temperature simultaneously
- Resolution: 0.1℃
- Display: T1, T2, â–³T
Respiration
- Thoracic impedance & nasal tube double method selectable
- Measurement range: 0~120bpm
- Accuracy: ±1bpm
- Resolution: 1bpm
ETCO2 (Option)
- Measuring Method: main/side stream type
Measurement range: 0%-10.0% - Accuracy: ±2mmHgÂ
2-IBP (Invasive blood pressure) (Option)
- Measurement range: -10-300mmHg
Channel: max 4 channels - Accuracy:±1mmHg or ±2%
Transducer sensitivity: 5uV/V/mmHg - Pressure label: ART, CVP, RVP, LAP, RAP, PAP, ICP, LVP
Cardiac Output (Option)
- Measuring Method: Thermodilution
- Blood temperature measurement and alarm range: 23 ℃~ 43℃
- Unit: degrees Celsius ℃ or Fahrenheit ℉
- Error: ±0.2 ℃
- Resolution: 0.1℃
- Cardiac output measurement range: 0.1L/min ~ 20.0 L/min
- Error: ±0.2 L/min or ±5%
- Power requirement: 100~240VAC, 50/60Hz