{"product_id":"newman-abi-q-system","title":"Newman Medical ABI-Q System","description":"\u003cp style=\"text-align:center\"\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cu\u003e\u003cstrong\u003eNewman Medical ABI-Q\u003c\/strong\u003e\u003c\/u\u003e\u003c\/span\u003e\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eNew simpleABI-Q - Fast and Easy\u003c\/li\u003e \t\u003cli\u003eNO DOPPLER - NO SPECIAL TRAINING\u003c\/li\u003e \t\u003cli\u003eWRAP A CUFF - RESULTS IN SECONDS\u003c\/li\u003e \t\u003cli\u003eACCURATE - Less chance for operator error, less affected by calcified arteries of many diabetics, not affected by cold toes\/fingers\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cbr\u003e \u003cspan style=\"font-size:12px\"\u003e\u003cstrong\u003eWHY PAD TESTING SHOULD BE DONE IN YOUR PRACTICE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003ePAD testing saves patient's lives, improves their health\u003c\/li\u003e \t\u003cli\u003ePeripheral artery disease, PAD, is a serious disease - with deadly consequences\u003c\/li\u003e \t\u003cli\u003eMortality is higher than many common diseases you test for\u003c\/li\u003e \t\u003cli\u003eEarly diagnosis and treatment can avoid disability and improve quality of life\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cbr\u003e \u003cstrong\u003eIf you don't test, most PAD will be missed\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eHistory and physical exam are unreliable\u003c\/li\u003e \t\u003cli\u003eOver half of PAD patients are asymptomatic or believe their pains are arthritis or have stopped walking far enough to bring on claudication. As few as 10% have claudication.\u003c\/li\u003e \t\u003cli\u003eAsymptomatic patients have the same prognosis as those with symptoms\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cbr\u003e \u003cstrong\u003eYour patients prefer that testing be done in your office\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eValidates your patient's trust in you to find their PAD before they have an MI, stroke or amputation\u003c\/li\u003e \t\u003cli\u003eThey appreciate having it done in your office rather than be sent elsewhere\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cbr\u003e \u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e Powerful yet simple ABI-Q software saves you time and is what sets the ABI-Q system apart. The software is an integrated part of the system; no separate downloading of the data is needed.\u003cbr\u003e  \u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eAutomatic index calculations, avoiding potential errors\u003c\/li\u003e \t\u003cli\u003eAutomatically stores each exam with time stamp\u003c\/li\u003e \t\u003cli\u003eYour logo and contact information can be shown on the report\u003c\/li\u003e \t\u003cli\u003eYour physicians, operators and interpreters can be on drop-down editable menus\u003c\/li\u003e \t\u003cli\u003eDrop down ICD-10 codes\u003c\/li\u003e \t\u003cli\u003eSuggested CPT codes and interpretation of results are shown\u003c\/li\u003e \t\u003cli\u003eMultiple and selectable formats to store the reports: PDF, TIFF, CSV, BMP, JPG DICOM software is available as an option\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cbr\u003e \u003cstrong\u003eReports\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e The ABI-Q software provides a fast, effective global test for the presence of PAD\u003cbr\u003e \u003cbr\u003e ABI-Q Exam - The ABI-Q exam utilizes the PVR waveform - a diagnostic tool that has been used in vascular diagnosis for decades.\u003cbr\u003e \u003cbr\u003e \u003cstrong\u003ePVR\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e Each ABI-Q comes with PVR hardware which quickly and easily produces vascular waveforms.\u003cbr\u003e \u003cbr\u003e \u003cstrong\u003eCuffs\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e The ABI-Q system comes with a complete set of specialized vascular cuffs. They are a washable soft material over a non-latex bladder. The cuffs are long enough to completely encircle the limb. The set includes: 2 x 10cm\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eHow does the ABI-Q work?\u003c\/strong\u003e\u003c\/p\u003e  \u003cp style=\"margin-left:.5in\"\u003eThe ABI-Q is based on our PVR waveforms.  The PVR has been a staple of vascular testing for over 30 years.  Recent studies have shown that it can have 97% accuracy compared to ultrasound duplex scanning.  Recognizing that interpreting a waveform can be subjective, we digitize the waveform and calculate a numerical index similar to (but not identical to) the standard ABI:\u003c\/p\u003e  \u003cp style=\"margin-left:3.0in\"\u003e\u0026gt;1.0 Normal\u003c\/p\u003e  \u003cp style=\"margin-left:3.0in\"\u003e0.91-0.99 Borderline\u003c\/p\u003e  \u003cp style=\"margin-left:3.0in\"\u003e\u0026lt;0.90 At risk for PAD\u003c\/p\u003e  \u003cp style=\"margin-left:.5in\"\u003eIt has been tested on over 120 patients and has an accuracy of better than 94%.\u003c\/p\u003e  \u003cp style=\"margin-left:.5in\"\u003eMany patients, especially diabetics, have calcified incompressible arteries (hardening of the arteries).  When this occurs, it throws off the pressure readings and the ABI results may not be accurate.  This does not happen with the ABI-Q.\u003c\/p\u003e  \u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e \t\u003ctbody\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"height:25px; width:102px\"\u003e \t\t\t\u003cp\u003eManufacturer\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:25px; width:126px\"\u003e \t\t\t\u003cp\u003eProduct\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:25px; width:150px\"\u003e \t\t\t\u003cp\u003eStreet price\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:25px; width:150px\"\u003e \t\t\t\u003cp\u003eTechnique\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:25px; width:189px\"\u003e \t\t\t\u003cp\u003eComments\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"height:37px; width:102px\"\u003e \t\t\t\u003cp\u003eHuntleigh\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:37px; width:126px\"\u003e \t\t\t\u003cp\u003eABIlity\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:37px; width:150px\"\u003e \t\t\t\u003cp\u003e$4499 w\/o computer\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:37px; width:150px\"\u003e \t\t\t\u003cp\u003eSecondary cuffs to take pressures for ABI\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:37px; width:189px\"\u003e \t\t\t\u003cp\u003e8 cuffs – must be positioned correctly. May be affected by calcified arteries\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"height:39px; width:102px\"\u003e \t\t\t\u003cp\u003eCooper Surgical\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:39px; width:126px\"\u003e \t\t\t\u003cp\u003eVanMax\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:39px; width:150px\"\u003e \t\t\t\u003cp\u003e$3900 w\/o computer\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:39px; width:150px\"\u003e \t\t\t\u003cp\u003e4 cuff oscillometric for ABI\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:39px; width:189px\"\u003e \t\t\t\u003cp\u003eMay be affected by calcified arteries\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"height:39px; width:102px\"\u003e \t\t\t\u003cp\u003eMESI\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:39px; width:126px\"\u003e \t\t\t\u003cp\u003eMESI ABIP MD\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:39px; width:150px\"\u003e \t\t\t\u003cp\u003e$2750? w\/o computer\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:39px; width:150px\"\u003e \t\t\t\u003cp\u003e3 cuff oscillometric for ABI\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:39px; width:189px\"\u003e \t\t\t\u003cp\u003eABI based on only one arm, may be affected by calcified arteries. Made in Slovenia.  No longer available from distribution?\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"height:5px; width:102px\"\u003e \t\t\t\u003cp\u003eSemler\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:5px; width:126px\"\u003e \t\t\t\u003cp\u003eQuantaFlo\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:5px; width:150px\"\u003e \t\t\t\u003cp\u003e$650\/mo\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:5px; width:150px\"\u003e \t\t\t\u003cp\u003ePPG analysis to create “digital ABI”\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\t\u003ctd style=\"height:5px; width:189px\"\u003e \t\t\t\u003cp\u003eSuccessfully sells direct to insurers\u003c\/p\u003e  \t\t\t\u003cp\u003eAffected by cold fingers\/toes\u003c\/p\u003e  \t\t\t\u003cp\u003eNo distributor sales\u003c\/p\u003e \t\t\t\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e ","brand":"Newman Medical","offers":[{"title":"Default Title","offer_id":46350468219011,"sku":"ABI-Q","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/Newman-ABI-Q_002a6e53-70a7-4127-b3e5-a2fe1df584b6.jpg?v=1768284182","url":"https:\/\/discountcardiology.com\/products\/newman-abi-q-system","provider":"Discount Cardiology","version":"1.0","type":"link"}