{"product_id":"philips-m2636b-telemon-patient-monitor","title":"Philips M2636B Telemon Patient Monitor","description":"\u003cp\u003e The   Philips M2636B Telemon is indicated for use in the monitoring,   recording, and alarming of multiple physiologic parameters in adult and   pediatric patients to gain information for treatment, to monitor   adequacy of treatment, or to exclude causes of symptoms. TeleMon is a   prescription device for use in healthcare facilities by trained   healthcare professionals. TeleMon is not intended for home use.\u003c\/p\u003e \u003cp\u003e  \u003c\/p\u003e \u003cp\u003e \u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e \u003col\u003e   \u003cli\u003e ·          Maximum Pressure: 280 mmHg\u003c\/li\u003e   \u003cli\u003e ·          Overpressure Safety Limit: 300 mmHg (max)\u003c\/li\u003e   \u003cli\u003e ·          Accuracy: 5% of reading (whichever is greater)\u003c\/li\u003e   \u003cli\u003e ·          Heart Rate Range: 40 to 200 b\/min\u003c\/li\u003e   \u003cli\u003e ·          Cuff Deflation Rate: 6 mmHg\/step\u003c\/li\u003e   \u003cli\u003e ·          NBP Alarm Range at Central: 10 to 260 mmHg\u003c\/li\u003e   \u003cli\u003e ·          Rated Life: 30,000 measurement cycles (36\/day for 2.3 years)\u003c\/li\u003e   \u003cli\u003e ·          Cuff Inflation Time: 60 sec maximum\u003c\/li\u003e   \u003cli\u003e ·          Limitations on Use: Not for use on neonates.\u003c\/li\u003e   \u003cli\u003e ·          When used on patients suffering from cardiac arrhythmias, information presented will have undefined accuracy.\u003c\/li\u003e   \u003cli\u003e ·          Auto Mode Repetition Time: 5, 10, 15, 30, 60 or 120 minutes\u003c\/li\u003e   \u003cli\u003e ·          Measurement Time (average @ HR \u0026gt; 60 b\/ min): Auto\/Manual mode: 30 sec (average)\u003c\/li\u003e   \u003cli\u003e ·        Auto\/Manual mode: 170 sec (maximum)\u003c\/li\u003e \u003c\/ol\u003e \u003cp\u003e  \u003c\/p\u003e \u003ch3\u003e Safety Standards\u003c\/h3\u003e \u003cp\u003e The   M2636B TeleMon B Monitor complies with the Council Directive 93\/42\/EEC   of 14 June, 1993 concerning medical devices, and carries CE marking   accordingly (CE 0123).\u003cbr\u003e   The following accessories and system components are independently CEmarked:\u003cbr\u003e   Power Supply accessory Battery and Battery Reconditioner accessory\u003c\/p\u003e \u003ch3\u003e Telemetry System\u003c\/h3\u003e \u003cp\u003e Note—The Battery Reconditioner is not for use in the patient vicinity.\u003cbr\u003e   \u003cbr\u003e   The M2636B TeleMon B also complies with the following international safety regulations for medical electrical equipment:\u003cbr\u003e   IEC 60601-1\/ EN 60601-1\u003cbr\u003e   IEC 60601-1-1\/ EN 60601-1-1\u003cbr\u003e   IEC 60601-1-2\/ EN 60601-1-2\u003cbr\u003e   CAN\/ CSA C22.2 No. 601.1-M90\u003cbr\u003e   UL 2601-1\u003cbr\u003e   \u003cbr\u003e   This CISPR-11 Class A, Group 1 device is not suitable for use in a   domestic establishment or one that is connected directly to the low   voltage public mains. The monitor is a Class 1 device and has an IPX 1   rating (excluding the power supply). The device has BF and CF applied   parts. The system provides continuous operation when in use.\u003cbr\u003e   \u003cbr\u003e   Non-invasive blood pressure measurements determined with this device   are equivalent to those obtained by a trained observer using the   cuff\/stethoscope auscultation method, within the limits prescribed by   the American National Standard, Electronic or automated   sphygmomanometers. Diastolic values correspond to Phase 5 Korotkoff   sounds. The NPB portion of the device also meets all relevant parts of   the following safety standards:\u003cbr\u003e   ANSI\/AAMI SP10\u003cbr\u003e   IEC 60601-2-30\u003cbr\u003e   \u003cbr\u003e   NBP internal operating software ensures that:\u003cbr\u003e   Maximum cuff inflation time is limited to 60 seconds.\u003cbr\u003e   Duration of blood pressure reading is limited to 170 seconds.\u003c\/p\u003e \u003ch3\u003e Electrical Specifications\u003c\/h3\u003e \u003cp\u003e Line Power\u003cbr\u003e   Power Input An external power supply is used.\u003cbr\u003e   Input 100-250 VAC +6%\/-10%; 50-60 Hz +\/-6%\u003cbr\u003e   Input Power Average (36 Watts, 64 VA), Max (39 Watts, 81 VA)\u003cbr\u003e   Output 18 VDC\u003cbr\u003e   Battery Type 10.8V Nickel Metal Hydride Battery NI1030AG\u003cbr\u003e   (NiMH Smart Battery, package style DR 35), M4790A\u003cbr\u003e   Operating Time Typical 5 hours at 25º C (77º F) with %SpO2 and NBP measurements 4 times\/hour: up to 3.5 hours\u003cbr\u003e   Charge Time From 15% of capacity to fully charged: 2-3 hours typical at 25º C (77º F), TeleMon on or off\u003cbr\u003e   Electrodes Compatible with EC-12 electrodes only\u003c\/p\u003e \u003ch3\u003e Environmental Specifications\u003c\/h3\u003e \u003cp\u003e Operating Temperature Range Monitor without NBP Cuff: 0º C to 35º C (32º F to 95º F)\u003cbr\u003e   Monitor with NBP Cuff: 10º C to 35º C (50º F to 95º F)\u003cbr\u003e   Altitude Range Up to 3048 m (10,000 ft.)\u003cbr\u003e   Humidity Range \u0026lt; 90% relative humidity at 35º C (95º F), noncondensing\u003c\/p\u003e ","brand":"Philips","offers":[{"title":"Select Accessory","offer_id":46360621940867,"sku":"M2636B1","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Assorted BP cuff kit","offer_id":46360621973635,"sku":"M2636B2","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/Philips-M2636B-Telemon-Patient-Monitor-01_ae0160ba-40f2-42f8-bb64-eb3c10dbddfa.jpg?v=1768284216","url":"https:\/\/discountcardiology.com\/products\/philips-m2636b-telemon-patient-monitor","provider":"Discount Cardiology","version":"1.0","type":"link"}