{"product_id":"philips-respironics-loflo-sidestream-co2-sensor-module","title":"Philips Respironics LoFlo Sidestream CO2 Sensor Module","description":"\u003ch1 style=\"text-align: center;\"\u003ePhilips Respironics LoFlo Sidestream CO2 Sensor Module \u003c\/h1\u003e  \u003ch1\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cstrong\u003eDEMO UNIT, 1 YEAR WARRANTY\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e  \u003cp\u003eAs a recognized global leader in capnography, Respironics has been providing innovative and cost effective solutions for over 20 years. The LoFlo sensor is the ideal capnography solution for all your CO\u003csub\u003e2\u003c\/sub\u003e monitoring requirements. Respironics provides comprehensive technical, clinical, and marketing support to help meet the growing needs of your business.\u003c\/p\u003e  \u003cp\u003eFeatures\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eIdeal for non-intubated patients\u003c\/li\u003e \t\u003cli\u003eProprietary sample cell protects internal NDIR components from contamination\u003c\/li\u003e \t\u003cli\u003eCommon connector allows easy exchange between mainstream and sidestream monitoring\u003c\/li\u003e \t\u003cli\u003eRobust and long life pump reduces periodic maintenance\u003c\/li\u003e \t\u003cli\u003eNo calibration required\u003c\/li\u003e \t\u003cli\u003eUnique accessories \u0026amp; supplies for all patients\u003c\/li\u003e \t\u003cli\u003ePrivate label option\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003eInternal or External Application...\u003c\/p\u003e  \u003cp\u003eRespironics offers the LoFlo engine for internal integration into your monitoring system.\u003c\/p\u003e  \u003cp\u003eIt's your choice!\u003c\/p\u003e  \u003cp\u003eThe LoFlo sensor's small, lightweight package is designed to be shared. It is easily moved from room to room to connect to your device or during transport.\u003c\/p\u003e  \u003cp\u003eMounting Options!\u003c\/p\u003e  \u003cp\u003eMount the sensor to a bed rail, IV pole, or leave as part of the system cabling.\u003c\/p\u003e  \u003cp\u003e \u003c\/p\u003e  \u003cp\u003e \u003c\/p\u003e  \u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e \t\u003ctbody\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eSample Flow Rate \u003c\/td\u003e \t\t\t\u003ctd\u003e50 mL\/minute ±10 mL\/minute \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003ePrinciple of Operation \u003c\/td\u003e \t\t\t\u003ctd\u003eNon-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eInitialization Time \u003c\/td\u003e \t\t\t\u003ctd\u003eCapnogram, displayed in less than 20 seconds, at an ambient temperature of 25°C, full specifications within 2 minutes \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eCO2Measurement Range \u003c\/td\u003e \t\t\t\u003ctd\u003e0 to 150 mmHg, 0 to 19.7%, 0 to 20 kPa \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eCO2 Resolution \u003c\/td\u003e \t\t\t\u003ctd\u003e \t\t\t\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e \t\t\t\t\u003ctbody\u003e \t\t\t\t\t\u003ctr\u003e \t\t\t\t\t\t\u003ctd\u003e0.1 mmHg \u003c\/td\u003e \t\t\t\t\t\t\u003ctd\u003e0 to 69 mmHg\u003c\/td\u003e \t\t\t\t\t\u003c\/tr\u003e \t\t\t\t\t\u003ctr\u003e \t\t\t\t\t\t\u003ctd\u003e0.25 mmHg\u003c\/td\u003e \t\t\t\t\t\t\u003ctd\u003e70 to 150 mmHg\u003c\/td\u003e \t\t\t\t\t\u003c\/tr\u003e \t\t\t\t\u003c\/tbody\u003e \t\t\t\u003c\/table\u003e \t\t\t\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eCO2 Accuracy \u003c\/td\u003e \t\t\t\u003ctd\u003e \t\t\t\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e \t\t\t\t\u003ctbody\u003e \t\t\t\t\t\u003ctr\u003e \t\t\t\t\t\t\u003ctd\u003e0 – 40 mmHg \u003c\/td\u003e \t\t\t\t\t\t\u003ctd\u003e±2 mmHg \u003c\/td\u003e \t\t\t\t\t\u003c\/tr\u003e \t\t\t\t\t\u003ctr\u003e \t\t\t\t\t\t\u003ctd\u003e41 – 70 mmHg \u003c\/td\u003e \t\t\t\t\t\t\u003ctd\u003e±5% of reading \u003c\/td\u003e \t\t\t\t\t\u003c\/tr\u003e \t\t\t\t\t\u003ctr\u003e \t\t\t\t\t\t\u003ctd\u003e71 – 100 mmHg \u003c\/td\u003e \t\t\t\t\t\t\u003ctd\u003e±8% of reading \u003c\/td\u003e \t\t\t\t\t\u003c\/tr\u003e \t\t\t\t\t\u003ctr\u003e \t\t\t\t\t\t\u003ctd\u003e101 – 150 mmHg \u003c\/td\u003e \t\t\t\t\t\t\u003ctd\u003e±10% of reading \u003c\/td\u003e \t\t\t\t\t\u003c\/tr\u003e \t\t\t\t\t\u003ctr\u003e \t\t\t\t\t\t\u003ctd colspan=\"2\"\u003eAbove 80 BPM ±12% of reading \u003c\/td\u003e \t\t\t\t\t\u003c\/tr\u003e \t\t\t\t\u003c\/tbody\u003e \t\t\t\u003c\/table\u003e \t\t\t\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eCO2 Stability \u003c\/td\u003e \t\t\t\u003ctd\u003eShort term drift: Drift over four hours shall not exceed 0.8 mmHg maximum \u003cbr\u003e \t\t\tLong term drift: Accuracy specification will be maintained over a 120-hour period \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eCO2 Noise \u003c\/td\u003e \t\t\t\u003ctd\u003eRMS noise of the sensor is less than or equal to 0.25 mmHg at 5% CO2\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eSampling Frequency \u003c\/td\u003e \t\t\t\u003ctd\u003e100 Hz \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eRespiration Rate Range \u003c\/td\u003e \t\t\t\u003ctd\u003e0 to 150 Breaths Per Minute (BPM) \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eRespiration Rate Accuracy \u003c\/td\u003e \t\t\t\u003ctd\u003e±1 breath \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eCompensations (Supplied by Host) \u003c\/td\u003e \t\t\t\u003ctd\u003eBarometric pressure: 400 mmHg to 800 mmHg \u003cbr\u003e \t\t\tOperator selectable O2, N2O, HE and agent compensation \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eCalibration \u003c\/td\u003e \t\t\t\u003ctd\u003eNo routine user calibration required \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eSample Cell\/Filter \u003c\/td\u003e \t\t\t\u003ctd\u003eProprietary single patient use sample cell and inline filter are integrated with the sample line which effectively eliminates contamination of the internal system \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eNasal Sampling Kits for Non-intubated Patients \u003c\/td\u003e \t\t\t\u003ctd\u003eNasal CO2 or CO2 with O2 delivery (Adult,Pediatric,Infant-Neonatal) \u003cbr\u003e \t\t\tNasal\/Oral CO2 or CO2 with O2 delivery (Adult, Pediatric) \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eAirway Adapter Kits for Intubated Patients \u003c\/td\u003e \t\t\t\u003ctd\u003eAdult\/Pediatric with and without dehumidification tubing\u003cbr\u003e \t\t\tPediatric\/Infant, low deadspace, with and without dehumidification tubing \u003cbr\u003e \t\t\tTaper meets ISO 5356-1 \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eSample Kit Hours of Use \u003c\/td\u003e \t\t\t\u003ctd\u003eNasal and Oral\/Nasal Cannulas without nafion – up to 12 hours\u003cbr\u003e \t\t\tNasal and Oral\/Nasal Cannulas with nafion – up to 120 hours\u003cbr\u003e \t\t\tAirway Adapter Kits without nafion - up to 12 hours \u003cbr\u003e \t\t\tAirway Adapter Kits with nafion - up to 120 hours \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eSample Cell Detection \u003c\/td\u003e \t\t\t\u003ctd\u003eInsertion automatically turns sampling pump on. Removal automatically turns sampling pump off \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eFlow Control \u003c\/td\u003e \t\t\t\u003ctd\u003eVia ΔP measurement across a capillary tube \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eScavenging Port \u003c\/td\u003e \t\t\t\u003ctd\u003eYes \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eVoltage Requirements \u003c\/td\u003e \t\t\t\u003ctd\u003e5.0 VDC ±5% \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003ePower Rating \u003c\/td\u003e \t\t\t\u003ctd\u003eRated input: Less than 1.3 Watts typical \u003cbr\u003e \t\t\tSteady state less than 2.0 Watts maximum on power up (warm up) \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eInterconnection \u003c\/td\u003e \t\t\t\u003ctd\u003eStandard - Lemo Redel 8-pin plastic \u003cbr\u003e \t\t\tLoFlo and CAPNOSTAT are interchangeable with the host monitor Common connector allows easy exchange between mainstream and sidestream monitoring \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eTemperature and Humidity\u003c\/td\u003e \t\t\t\u003ctd\u003eOperating: 0° to 40°C, 10 to 90% RH, non-condensing \u003cbr\u003e \t\t\tStorage: -40° to 70°C, \u0026lt;90% RH, non-condensing \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eWater Resistance \u003c\/td\u003e \t\t\t\u003ctd\u003eIPX4 . Splash-proof (When sample cell is inserted in sample cell receptacle) \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eShock Impact \u003c\/td\u003e \t\t\t\u003ctd\u003eIEC TR 60721-4-7 Class 7M3 (designed to withstand environments subject to significant vibrations or high shock levels)\u003cbr\u003e \t\t\tEN60068-2-27 shock \u003cbr\u003e \t\t\tEN60068-2-64 random vibration \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eData Interface \u003c\/td\u003e \t\t\t\u003ctd\u003eRS232, bi-directional, 19200 baud, standard N-8-1 \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eData Output \u003c\/td\u003e \t\t\t\u003ctd\u003eCO2 gas concentration (mmHg), end-tidal CO2, inspired CO2, respiratory rate\u003cbr\u003e \t\t\tGas and barometric pressure compensated when supplied by host \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eRegulatory \u003c\/td\u003e \t\t\t\u003ctd\u003eDesigned to meet IEC 60601-1-2, EN55011 - CISPIR 11 Class B (Radiated and Conductive Emissions), IEC 61000-4-2 Electrostatic Discharge Immunity, IEC 61000-4-3 Radiated Immunity \u003cbr\u003e \t\t\tDesigned to comply with 93\/42\/EEC (MDD CE Marking), FDA Standards, ISO21647, and Medical Electrical Equipment performance requirements for the basic safety and essential performance of respiratory gas monitors \u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e  \u003cp\u003e \u003c\/p\u003e ","brand":"Philips","offers":[{"title":"Default Title","offer_id":46350491385987,"sku":"1022054","price":1595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/Philips_20Respironics_20LoFlo_20Sidestream_20CO2_20Sensor_20Discount_20Cardiology-01_df2b799d-780c-422f-bf54-4a3d37c4341e.jpg?v=1768284247","url":"https:\/\/discountcardiology.com\/products\/philips-respironics-loflo-sidestream-co2-sensor-module","provider":"Discount Cardiology","version":"1.0","type":"link"}