{"product_id":"quinton-q-stress-cardiac-stress-system","title":"Quinton Q-Stress Cardiac Stress System (Win 7)","description":"\u003cp\u003e\u003cstrong\u003eQuinton Q-Stress Stress System (Windows 7) Refurbished\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eCardiac Stress Test, Treadmill System\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe Quinton Q-Stress is the hospital industry's gold standard. Our cardiac stress test with treadmill system is the winner of multiple awards (most recently Frost \u0026amp; Sullivan's Market Engineering Award). Quinton Q-Stress is now in its ninth generation.\u003cbr\u003e \u003cbr\u003e \u003cstrong\u003eNew! Microvolt T-Wave Alternans\u003csup\u003eTM\u003c\/sup\u003e for Q-Stress combines the industry’s leading cardiac stress test system with Cambridge Heart’s unique Microvolt T-Wave Alternans (MTWA) testing system, creating the most comprehensive, reimbursable cardiac risk-profiling system in the industry (US only).\u003c\/strong\u003e The Analytic Spectral Method\u003csup\u003e®\u003c\/sup\u003e (ASM) detects every-other-beat patterns unique to patients at increased risk by analyzing the ECG in the frequency or spectral domain. Data shows that using frequency is superior at filtering out noise and artifact than using timing alone.\u003cbr\u003e \u003cbr\u003e The Cardiac Science \/ Quinton Q-Stress cardiac stress test with treadmill system is designed with you in mind. Its easy-to-learn left-to-right workflow and simple-to-understand icons and intuitive controls guide technicians through the stress test. Busy stress labs use QuikLists to enter comments quickly and efficiently.\u003cbr\u003e \u003cbr\u003e Our proprietary algorithm, baseline wander, and motion artifact filters reduce noise and produce clean ECG tracings even at high speeds and steep grades. Perfect for pharmacological stress tests as well. Patients will appreciate getting the best test results the first time.\u003cbr\u003e \u003cbr\u003e And Quinton Q-Stress is HL7 and DICOM compatible! Q-Stress has the flexibility to connect to your Healthcare IT systems in the way that works best for you to enhance your clinical workflow. \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eRobust network connectivity – DICOM or HL7 connects with virtually everything needed for enhanced workflow. It's compatible with your echo system, nuclear camera, EMR, HIS, PACs and other healthcare IT systems.\u003c\/li\u003e \t\u003cli\u003eFull disclosure reports; allows you to save the whole exam and review it at any time by exporting to your electronic medical record (EMR) system or hospital information system (HIS).\u003c\/li\u003e \t\u003cli\u003eIn-test review of stress testing data that includes \"rewind\" and \"freeze frame\" capabilities (both industry firsts) while still viewing the live test.\u003c\/li\u003e \t\u003cli\u003eEctopic capture and display for heartbeats outside the sinoatrial node.\u003c\/li\u003e \t\u003cli\u003eFully customizable panel display, plus the flexibility to add your own user-defined protocols.\u003c\/li\u003e \t\u003cli\u003eRisk scoring, procedural re-analysis, and extensive report formatting options.\u003c\/li\u003e \t\u003cli\u003eWarranty: 13-Month parts and labor.\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003e\n\u003cem\u003eConnectivity\u003c\/em\u003e. Bi-directional communications using HL7 or DICOM enables the import of demographics, billing and procedures codes to Q-Stress. Export comprehensive test reports to help minimize documentation errors and lost billings.\u003c\/li\u003e \t\u003cli\u003e\n\u003cem\u003eEase of use\u003c\/em\u003e. The system’s Microsoft Windows compatibility (Vista or XP), left-to-right flow, and intuitive controls guide users through the procedure.\u003c\/li\u003e \t\u003cli\u003e\n\u003cem\u003eAccuracy\u003c\/em\u003e. Tracings are accurate and clear, with clean waveforms even at high speeds and steep grades.\u003c\/li\u003e \t\u003cli\u003e\n\u003cem\u003eInstant replay\u003c\/em\u003e. The Freeze Frame option allows you to \"rewind\" and view any section of any lead during the test.\u003c\/li\u003e \t\u003cli\u003e\n\u003cem\u003eFull disclosure\u003c\/em\u003e. With the full disclosure option, you can save the entire cardiac stress test as a PDF and store it to your electronic records repository.\u003c\/li\u003e \t\u003cli\u003e\n\u003cem\u003eEasy analysis\u003c\/em\u003e. Built-in analysis tools allow modifications for new patient data or for physiologic changes – resting cardiac data remains constant for comparison.\u003c\/li\u003e \t\u003cli\u003e\n\u003cem\u003eCustomizable\u003c\/em\u003e. You decide how you want your patient's cardiac test data presented. Create custom reports based on physician's preference. Easy reporting. QuikLists enable fast, efficient preparation of your reports.\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e \u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eQ-Stress\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eQ-Stress, the eighth generation Burdick\/Quinton stress system, takes cardiac exercise testing to a new level of performance. With our 40+ years of technical and clinical leadership, we've tailored Q-Stress to offer extensive customization designed to meet your needs.\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eLatest software enhancements include: risk scoring, full disclosure, procedure re-analysis, freeze frame, and more\u003c\/li\u003e \t\u003cli\u003eClinical capabilities include: ECG full disclosure and archive, in-test ECG review, automated patient risk-scoring, dynamic ST display, ectopic beat capture, and much more\u003c\/li\u003e \t\u003cli\u003eAdvanced connectivity alternatives include: Q-Exchange, Networking, EMR, and IS options\u003c\/li\u003e \t\u003cli\u003eEase-of-use via simple controls and lists, efficient reporting, automated record export, customization, and a Windows-based environment\u003c\/li\u003e \t\u003cli\u003eDelivers superior trace quality and system reliability\u003c\/li\u003e \t\u003cli\u003eStorage capacity for tens of thousands of procedure reports\u003c\/li\u003e \t\u003cli\u003eInterfaces to the TM 55\/65 treadmills\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eSunTech Tango blood pressure monitor \u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eWorks with the Q-Stress system to automatically measure and display a patient's systolic and diastolic BP along with heart rate during the test. Makes use of SunTech's proprietary Dimensional K-Sound Analysis (DKA); a result of SunTech's pioneering work in 24-hour ambulatory BP monitoring.\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eDimensional K-Sound Analysis\u003c\/li\u003e \t\u003cli\u003eInterfaces to Q-Stress\u003c\/li\u003e \t\u003cli\u003eReal-Time Wave Form Display\u003c\/li\u003e \t\u003cli\u003eHistorical Tabular Data\u003c\/li\u003e \t\u003cli\u003eAutomatic or Manual Settings\u003c\/li\u003e \t\u003cli\u003eSimplified Patient Preparation\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eStress Echo Bed from Medical Positioning \u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eWhen a cardiac impaired patient cannot walk treadmill, but Echo images are desired, a thorough evaluation can still be conducted via the MPI Stress-Echo Bed. Supine ergometry can detect ischemia and provoke symptoms at lower heart rates.\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eIntegrated Ergometer Control\u003c\/li\u003e \t\u003cli\u003eMulti-Modality - Stress Echo and resting studies\u003c\/li\u003e \t\u003cli\u003eDual Drop Sections - Apical Access and Superior Ergonomics\u003c\/li\u003e \t\u003cli\u003eHighest Patient Weight Capacity\u003c\/li\u003e \u003c\/ul\u003e ","brand":"Burdick","offers":[{"title":"Default Title","offer_id":46350502559875,"sku":"QStress-Special","price":6495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/Quinton-Q-Stress-Cardiac-Stress-System-01_c9a391b8-58a7-4e21-9ced-2743e7f840e2.jpg?v=1768284273","url":"https:\/\/discountcardiology.com\/products\/quinton-q-stress-cardiac-stress-system","provider":"Discount Cardiology","version":"1.0","type":"link"}