{"product_id":"respirex-easyone-diagnostic-spirometer-demo","title":"RESPIREX EasyOne Diagnostic Spirometer (Demo)","description":"\u003cp style=\"text-align: center;\"\u003e  \t\u003cspan style=\"font-size:24px;\"\u003e\u003cstrong\u003eRESPIREX EasyOne Diagnostic Spirometer \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cstrong\u003eThe RESPIREX EasyOne Plus is a diagnostic spirometer that can perform a full range of tests (FVC, FVL, MVV). The \u003c\/strong\u003e\u003cstrong\u003eRESPIREX \u003c\/strong\u003e\u003cstrong\u003e EasyOne Diagnostic Spirometer is a fantastic unit at a fantastic price. \u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e  \t \u003c\/p\u003e  \u003cp\u003e  \tDiscount Cardiology recommends the easy-to-use \u003cstrong\u003eRESPIREX \u003c\/strong\u003e\u003cstrong\u003e EasyOne spirometer\u003c\/strong\u003e. It uses patented digital ultrasonic flow measurement technology for fast, accurate and reliable operation. The \u003cstrong\u003eRESPIREX \u003c\/strong\u003e EasyOne is designed for a wide range of testing in primary care, specialty physician, industrial and hospital settings. The \u003cstrong\u003eRESPIREX \u003c\/strong\u003e EasyOne offers automated comparison to predicted values, pre and post bronchodilator comparisons, and test quality control that automatically assesses quality control that automatically assesses patient effort and displays easy to understand messages that aid in patient coaching. The graphic display shows curves, and the optional color printout is easy to read and interpret. The single-patient-use breathing tube minimizes risk of cross-infection. Discount Cardiology likes the \u003cstrong\u003eRESPIREX \u003c\/strong\u003e Easy One spirometer because it is compact, stores up to 700 patient records, and is battery powered for true hand-held portability.\u003c\/p\u003e  \u003cp\u003e  \t\u003cspan id=\"ctl00_MainContentHolder_lblDescription\"\u003eThe \u003cstrong\u003eRESPIREX \u003c\/strong\u003e\u003cstrong\u003e EasyOne Spirometer\u003c\/strong\u003e incorporates an ultrasonic flow sensor to measure the flow of air in and out of the patients lungs. \u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cspan id=\"ctl00_MainContentHolder_lblDescription\"\u003eUltrasonic flow measurement eliminates problems associated with traditional methods of flow measurement and helps make the \u003cstrong\u003eRESPIREX \u003c\/strong\u003e\u003cstrong\u003eEasyOne spirometer\u003c\/strong\u003e extraordinarily fast, reliable, accurate, and mistake proof. There are no moving parts, no codes to enter, no screens to catch sputum, and no disposables to calibrate. Ultrasonic flow measurement is independent of gas composition, pressure, temperature, and humidity; and disqualifies mistakes due to these variables. \u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cspan id=\"ctl00_MainContentHolder_lblDescription\"\u003eTransistors located on the mouthpiece cavity transmit and accept sound in alternating directions. When gas flow is existent in the tube, a pulsation that moves against the flow is slowed down and takes a longer time to reach the opposite transducer. Conversely, a pulse traveling with the flow (traveling downstream) is sped up and takes a shorter time to reach the opposite transducer. \u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cspan id=\"ctl00_MainContentHolder_lblDescription\"\u003eThe sound waves travel time is precisely measured with a digital clock. The gas flow through the mouthpiece is then calculated from flow times. This calculation is independent of gas composition, pressure, temperature, and humidity; and eliminates errors due to these variables. \u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cspan id=\"ctl00_MainContentHolder_lblDescription\"\u003eThe disposable mouthpiece acts only as a hygienic barier and does not affect the flow of air or the reading by the transducers. Since the one time use spirette has no reading capabilities, it does not perform a measurement function and does not require calibration. \u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cspan id=\"ctl00_MainContentHolder_lblDescription\"\u003eTrueFlow, developed by ndd, is the new revolutionary way of directly measuring flow of inhaled and exhaled breath without the need for a mechanical sensor. \u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e  \t\u003cstrong\u003eEasyOne Screen Connector Kit (Optional)\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tfor connection of the EasyOne Screen to a PC\u003c\/li\u003e  \t\u003cli\u003e  \t\tdirect real time FV and FT curve\u003c\/li\u003e  \t\u003cli\u003e  \t\treject \/ accept feature\u003c\/li\u003e  \t\u003cli\u003e  \t\tchildren incentive screen\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \t\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \t\u003cli\u003e  \t\tUltrasonic Flow Measurement\u003c\/li\u003e  \t\u003cli\u003e  \t\tSingle patient use spirette\u003c\/li\u003e  \t\u003cli\u003e  \t\tAlpha Numeric Keypad\/Graphic Display\u003c\/li\u003e  \t\u003cli\u003e  \t\tGraphic Curve Display\u003c\/li\u003e  \t\u003cli\u003e  \t\tMeets ATS 1994 diagnostic standards\u003c\/li\u003e  \t\u003cli\u003e  \t\tMeets NIOSH\/OSHA and SSD guidelines\u003c\/li\u003e  \t\u003cli\u003e  \t\tCustomizable Configuration\u003c\/li\u003e  \t\u003cli\u003e  \t\tAutomated Coaching Messages and QC\u003c\/li\u003e  \t\u003cli\u003e  \t\tAutomated Interpretation\u003c\/li\u003e  \t\u003cli\u003e  \t\tTwo AA Batteries\u003c\/li\u003e  \t\u003cli\u003e  \t\tStores up to 700 test sessions\u003c\/li\u003e  \t\u003cli\u003e  \t\tOptional 8.5x11 or A4 printout\u003c\/li\u003e  \t\u003cli\u003e  \t\tPC Data Transfer\u003c\/li\u003e  \t\u003cli\u003e  \t\tToll free Technical Support\u003c\/li\u003e  \t\u003cli\u003e  \t\t1 Year Exchange Warranty\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e  \tAbout this unit\u003c\/p\u003e  \u003cp\u003e  \t \u003c\/p\u003e  \u003cp\u003e  \t\u003cspan id=\"Anthem_ctl00_MainContentHolder_lblDescription__\"\u003e\u003cspan id=\"ctl00_MainContentHolder_lblDescription\"\u003eThe \u003cstrong\u003eRESPIREX \u003c\/strong\u003e EasyOne Plus does not need to be calibrated. The use of a precision clock to measure flow time of ultrasonic pulses eliminates the need for calibration. Also, the placement of the transducer around the flow tube allows the measurements to remain independent of the flow. If you require a calibration syringe, we do sell the NDD 2030-2 3-liter calibration syringe. We do recommend having the spirometer checked on a regular basis to verify accuracy. The beauty of the \u003cstrong\u003eRESPIREX \u003c\/strong\u003e Spirometers is that they do not require a filter. Filters reduce the likelihood of cross contamination. However, since the flow is measured in a completely open tube, there is no risk of cross contamination once the spirette is changed. Most \u003cstrong\u003epft machines\u003c\/strong\u003e have a flow sensor that is exposed to exhaled breath and thus requires the filter. Since the \u003cstrong\u003eRESPIREX \u003c\/strong\u003e measurements are so precise, the use of this spirometer on children is recommended. The flow resolution is under 10 ml\/s! We owe this feat to the extremely low resistance that the spirette has. The spirette is ergonomical and would fit any human over the age of 5 years. For your convenience a few different predicted normal values may be chosen in the setup function. The \u003cstrong\u003eRESPIREX \u003c\/strong\u003e EasyOne Spirometer comes with a large internal memory. The unit auto-stores over 700 test sessions. This includes the patient's information, test results, and curves. A user may refer back to the memory at any time for viewing or to export via pc connectivity. If you do not want to export the reports, you may choose from a list of compatible printers. \u003cstrong\u003eRESPIREX \u003c\/strong\u003e did not integrate a printer because these lost cost thermal printers are likely to fade and they are hard to file. The \u003cstrong\u003eRESPIREX \u003c\/strong\u003e unit does not come with rechargable batteries. The power usage is so small that AA batteries suffice perfectly.  The EasyOne will keep your costs down. It does not need calibration, you will not need a calibration syringe, filters are a thing of the past, contamination is not a concern, and with a 3 year warranty you will have no maintenance. If you so wish, you may use a 22mm joint flange mask with the spirometer. Although it is not common, the spirometer does accomodate people who wish to use laedal masks with the spirette.\u003cbr\u003e  \t\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e  \t \u003c\/p\u003e  \u003cp\u003e  \t \u003c\/p\u003e  ","brand":"RESPIREX","offers":[{"title":"Default Title","offer_id":46350545551491,"sku":"2001-RESPIREX","price":1195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/ndd-easy-one-plus-spirometer-03_0edca22d-bac5-4d6b-aa13-86ead55a44d6.jpg?v=1768284177","url":"https:\/\/discountcardiology.com\/products\/respirex-easyone-diagnostic-spirometer-demo","provider":"Discount Cardiology","version":"1.0","type":"link"}