{"product_id":"tuttnauer-66-mid-range-series-autoclave","title":"Tuttnauer 66 Mid Range Series Autoclave","description":"\u003ch2 style=\"text-align: center;\"\u003e \tTuttnauer 66 Mid Range Series Autoclave\u003c\/h2\u003e \u003cp\u003e \t\u003cstrong\u003eThe autoclave operates with saturated steam as the sterilizing agent with a temperature range of 105 °C (221°F) to 138 °C (280 °F) and a working pressure that meets AMSE and PED requirements. Each autoclave model is available with either single or double door.\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003e\u003cimg height=\"133\" src=\"http:\/\/www.tuttnauer.com\/sites\/www.tuttnauer.com\/files\/66-vertical-sliding-door.png\" width=\"90\"\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t \u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003eVertical Sliding Door \u003c\/strong\u003e\u003cstrong\u003e​\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003e​\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003e\u003cimg height=\"133\" src=\"http:\/\/www.tuttnauer.com\/sites\/www.tuttnauer.com\/files\/66-automatic-hinged-door.png\" width=\"103\"\u003e\u003c\/strong\u003e\u003cstrong\u003e​\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t \u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003e     Automatic Hinged Door\u003c\/strong\u003e\u003cstrong\u003e​\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003eIDEAL FOR CSSD AND MEDICAL CENTERS\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003eThe 66 autoclave series is designed to cover a large field of applications for hospitals, CSSD and medical centers. The autoclave series has a chamber volume ranging in size from 340 to 600 liters.\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003eThe 66 series is available with two door options:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eFully automatic vertical sliding door\u003c\/strong\u003e\n\u003c\/li\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eHinged door with automatic locking\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \t\u003cstrong\u003eENGINEERED WITH PEOPLE IN MIND\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003eTuttnauer autoclaves are built to last longer, perform consistently, and comply with the strictest international standards. Autoclave chambers are constructed of long lasting 316L grade stainless steel with superior corrosion resistance. The chambers are fully jacketed for uniform heat distribution. The generator and piping are constructed of stainless steel. The pneumatic valves are air pressure operated, significantly reducing maintenance. We work to keep our autoclaves state of the art.\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003eSAFETY IS OUR TOP PRIORITY\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003eDoor Safety\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \t\u003cstrong\u003eThe doors are designed with independent mechanical and digital safety features that guarantee a safe working of the sterilizer.\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \t\u003cli\u003e \t\t\u003cstrong\u003e\u003cimg alt=\"66 Mid Range Autoclave Series\" height=\"161\" hspace=\"10\" src=\"http:\/\/www.tuttnauer.com\/sites\/www.tuttnauer.com\/files\/assets\/products\/medical-sterilizers\/66_sterilizer_image.jpg\" width=\"200\"\u003eA safety device prevents the operator from opening the door when chamber is pressurized\u003c\/strong\u003e\n\u003c\/li\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eSteam is not allowed into the chamber when the door is open\u003c\/strong\u003e\n\u003c\/li\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eA cycle will not start if the door is open or not properly closed\u003c\/strong\u003e\n\u003c\/li\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eThe door cannot open until chamber pressure reaches room pressure\u003c\/strong\u003e\n\u003c\/li\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eSliding Door Safety -The sliding door progress will automatically stop if an obstruction is detected\u003c\/strong\u003e\n\u003c\/li\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eDouble Door Safety – interlocks prevent both doors from being opened simultaneously\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \t\u003cstrong\u003eGeneral Safety Features:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eDouble Independent Monitoring: The combined digital and mechanical monitoring provides a cross reference and guarantees accurate results. The operator has two independent means to monitor temperature and pressure.\u003c\/strong\u003e\n\u003c\/li\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eSafety Valves: Both the chamber and the jacket are equipped with safety valves –if the pressure exceeds the allowed limit the safety valves will discharge.\u003c\/strong\u003e\n\u003c\/li\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eBuilt-in Steam Generator Safety: A water level monitoring system maintains a constant water level and ensures safe operation of the heaters.\u003c\/strong\u003e\n\u003c\/li\u003e \t\u003cli\u003e \t\t\u003cstrong\u003eEmergency Shut-Off: Easily accessible emergency switches for immediate and safe shut down of the sterilizer.\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e ","brand":"Tuttnauer","offers":[{"title":"Default Title","offer_id":46350685700227,"sku":"66M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/0891\/4563\/files\/Tuttnauer_2066_20Mid_20Range_20Series_20Autoclaves_20Discount_20Cardiology-01_64d12e24-c14f-420c-919f-8e62974f0795.png?v=1768284415","url":"https:\/\/discountcardiology.com\/products\/tuttnauer-66-mid-range-series-autoclave","provider":"Discount Cardiology","version":"1.0","type":"link"}