Description
Versatile, portable, and lightweight, the BM3 Plus monitor is specially designed to be reliable and user-friendly. The compact design, coupled with a unique handle, make it easy to move from room to room. It’s 8.4″ widescreen color monitor displays all the vital signs in different colors for easy recognition. A built in printer offers hard copy documentation of all measured values, as well as up to 3 waveforms of information. Alarms and settings are easily adjustable and are retained after turning off the power.
Includes:
- ECG, SpO2, NIBP, respiration and temperature.
- Pacemaker detection indicated on the ECG waveform display.
- 58mm built-in chart recorder – graphical and tabular trends of printing.
- Visible alarm lamp handle.
- 8.4″ color high resolution TFT screen.
- Battery operation.
- SpO2 pitch tone.
Options:
5 Lead ECG Cable, Temperature Probe (Skin), Temperature Probe (Skin or Esophogeal/Rectal)
Features:
3 YEAR WARRANTY (3 months on accessories)
Superior Advantages
• ECG, SpO2, NIBP, respiration and temperature.
• 8.4″ color high resolution TFT screen.
• Individual sweep speed setting for each parameter.
• Multiple display modes.
• Remembers your settings.
• Usable for adult to neonatal patient.
Enhanced Data Management
• 128 full hours trend and alarm information are stored.
• Continuous and spot-check mode.
• 20 unique 8 second waves are stored.
Transportable
• Li-ion rechargeable battery allows cordless use for up to 2 hours.
• Less than 3kg (7 lbs) including battery.
| GENERAL | Monitor Performance Specifications |
| Display, Resolution | 8.4" color TFT, 800 x 600 pixels |
| Dimension, Weight | 238 (w) x 250 (h) x 163 (d) mm. Approx. 3.1 kg |
| Indicators | Up to 3 waves (ECG, SpO2, Respiration) |
| Categorized alarms (3 priority levels) | |
| Visual alarm lamp | |
| Heart rate, SpO2 tone | |
| Battery status | |
| External power LED | |
| Interfaces | DC input connector: 18 VDC, 2.5A |
| Defib Sync Output | |
| - Signal Level: 0 to 5 V pulse | |
| - Pulse Width: 100 +/- 10ms | |
| LAN digital output for transferring data | |
| VGA output | |
| Battery | Bettery Type: Li-ion |
| Battery status indicator | |
| Operating Time: 2 hours typically (fully charged) | |
| Thermal Printer (optional) | Speeds: 25, 50 mm/sec |
| Paper width: 58 mm | |
| Graphical and Tabular Trends | |
| Tabular Trends | Memory Storage: 24 hours |
| Data Interval: 1, 5, 15, 30 min., and 1 hour | |
| Tabular Format: One table for all variables | |
| Graphical Trends | Display Duration: 30, 60, 90 min, 3, 6, 12 hours |
| Accessories | |
| Standard Accessories | 3- lead ECG cable - 1 ea. |
| Electrodes - 10 ea. | |
| NIBP extension tube, 3m long - 1 ea. | |
| Adult Cuff, 25-35 cm, reusable - 1 ea. | |
| SpO2 sensor extension cable (2m) - 1 ea. | |
| SpO2 sensor reusable - 1 ea. | |
| DC adapter, 18VDC, 2.5A - 1 set | |
| Optional Accessories | Temperature probe, Surface / Skin, reusable |
| 5 lead patient cable | |
| Neonate cuff | |
| Child cuff | |
| Data Storage | 120 Hours trends |
| 20 cases of 10 sec alarm waveform | |
| Language | English, French, Spanish, Italian, German, Chinese |
| *Interpretive results are intended only as guidance for the qualified physicians and must not be relied upoon as diagnosis | |
| PERFORMANCE | |
| ECG | |
| Leads | 3 lead, 5 leads(optional) |
| Heart Rate Range | 30 - 300 bpm |
| Hearth Rate Accuracy | +/- 3 bpm |
| Bandwidth | 0.5 Hz to 40 Hz |
| ECG Size (Sensitivity) | 0.5, 1, 2, 4 mV / cm |
| Pacemaker Detection Mode | Indicator on waveform display, user selectable |
| Differential Input Impedance | >5 mo |
| CMRR | >90 db at 50 or 60 Hz |
| Input Dynamic Range | +/- 5 mVAC, +/- 300 mVDC |
| Defribrillator Discharge | <4 sec |
| Lead-Off Detection | Yes |
| SpO2 | |
| % Saturation Range | 0% to 100% |
| Saturation Accuracy | 70 to 100% +/- 2 digits |
| 0 to 69% unspecified | |
| Pulse Rate Range | 0 to 254 bpm |
| Pulse Rate Accuracy | +/- 2 bpm |
| NIBP | |
| Measurement Modes | Manual: Single measurment |
| Auto: Automatic intervals of 1, 2, 3, 4, 5, 10, 15, 20, 30 min. and 1, 2, 4, 8, hr. | |
| STAT: Continous measurement of 5 min | |
| Cuff Presure Display | 0 to 300 mmHg |
| B.P. measurement range | Adult |
| - Systolic: 50 to 260 mmHg | |
| - Mean : 30 to 220 mmHg | |
| - Diastolic: 20 to 200 mmHg | |
| Pediatric | |
| - Systolic: 20 to 230 mmHg | |
| - Mean: 30 to 190 mmHg | |
| - Diastolic: 20 to 170 mmHg | |
| Neonate | |
| - Systolic: 50 to 120 mmHg | |
| - Mean: 30 to 100 mmHg | |
| - Diastolic: 20 to 90 mmHg | |
| Respiration | |
| Range | 5 to 120 breaths / min |
| Accuracy | +/- 3 breaths/min |
| Temperature Unit | |
| Range | 15° C to 45° C (59° F to 113° F) |
| Accuracy | +/- 0. 1°C |
| Compatible with | YS1 Series 400 temperature probes |
